Delivery Content; Safety Instructions; Preparing Installation - Renkforce UP 160 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions
Flush-mounting 160° motion detector
Item no. 1034032
Intended use
The product features a PIR sensor that responds to temperature changes within the
detection area, for example when a human being or larger animal enters the detection
area. The product is only intended for installation in a suitable, properly installed
flush-mounted box. It is possible to connect an electric load such as a light that gets
activated via PIR sensor.
For safety and approval purposes (CE), you must not rebuild and/or modify this product.
If you use the product for purposes other than those described above, the product may
be damaged. In addition, improper use can cause hazards such as short circuiting,
fire, electric shock etc. Read the instructions carefully and keep them. Make this
product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All
company names and product names are trademarks of their respective owners. All
rights reserved.

Delivery content

• Motion detector
• Operating instructions

Safety instructions

Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on
proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may
become dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong
jolts, high humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of
operation and protect it from any accidental use. Safe operation can no
longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a
low height can damage the product.
• Also observe the safety and operating instructions of any other devices
which are connected to the product.
• Operate the product using a common household supply voltage of
220 – 240 V/AC, 50 Hz only.
• The product is only suitable for fixed installation.
• For installations in industrial facilities, follow the accident prevention
regulations for electrical systems and equipment of the government
safety organization or the corresponding authority for your country.
• Consult an expert when in doubt about operation, safety or connection of
the device.
• Maintenance, modifications and repairs are to be performed exclusively
by an expert or at a qualified shop.
• If you have questions which remain unanswered by these operating
instructions, contact our technical support service or other technical
personnel.
Function of the motion detector
• The PIR sensor integrated in the product responds to temperature changes within
the detection range. Such is the case when humans or animals, whose temperatures
differ from the ambient temperature, enter the detection range.
• In order to allow for maximum detection, the product should be positioned in such
a way that the object to be detected does not walk towards the motion detector but
crosses the detection range from left to right or vice versa. Keep that in mind when
installing the product.
• The range of detecting temperature changes depends on a variety of factors:
- Installation height
- Ambient temperature
- Temperature difference between the moving object and the environment
- Size of the object
- Distance between object and product
- Direction and speed of motion
Detecting temperature changes through glass is basically not possible. Do
not install the product behind a pane of glass.

Preparing installation

Installation of the product must be carried out by a qualified professional
(i.e. an electrician) who is familiar with all applicable regulations!
When handling mains voltage improperly, you will not only endanger
yourself but also others!
If you do not have the relevant expert knowledge, do not install the product
yourself, but have it done by an expert.
• Only install the product in a suitable flush-mounted box.
• The product must be secured via an existing sub-distribution unit with a 10/16A fuse.
This setup requires the installation of an upstream residual current circuit breaker
(FI switch).
• The product must be completely free of voltage for installation.
• Turn off the corresponding circuit breaker and/or automatic fuse to remove all
voltage from the power circuit. Secure them against unauthorized restart, e.g. by
installing a warning sign. Also switch off the relevant circuit breaker in order to
disconnect all poles of the mains cable from the mains supply.
• Check the power circuit for any remaining voltage using an appropriate measuring
device.