FIG. 7-E: Vent Installation
2' Min.
Ceiling
Plate Spacers
12'
Min.
Ceiling
Plate
Spacer
Lances
FIG. 8-A
ROUGH-IN INSTRUCTIONS
Listed
Vent Top
Storm Collar
Roof Flashing
Oval to
Round
Adapter
Listed "BW"
Vent Pipe
Base Plate
Header Plate
2 x 4
Wall Studs
B-W Vent
STEP 6.
WARNING:
thermostat properly or to wire the furnace
correctly may result in continuous
!
operation, control damage or failure to
operate. This can cause property damage,
personal injury, or loss of life.
Follow the instructions included with the thermostat. Locate the
thermostat approximately five (5') feet above the floor and four feet
(4') from appliance. Always mount the thermostat on an inside wall
where it won't be affected by heat or cold sources such as direct
sunlight, televisions, fireplaces, hidden hot or cold water pipes,
drafts, etc. The thermostat must never be installed in an adjoining
room where a door can be closed between the thermostat and wall
furnace. Do not use more thermostat wire than is included with
the wall furnace. Do not run thermostat wire in same stud space
with vent. Conceal wire inside wall or secure to wall with insulated
staples that are included. Your furnace is shipped with a wall
thermostat (See page 34-35).
STEP 7.
To place furnace into position, grasp furnace and lift so furnace flue
vent and header plate vent opening engage. Do not use burner or
gas control to lift heater. Lift furnace upward and swing bottom into
wall opening until legs rest on floor plate and are flush to finished
wall. For proper combustion, level heater front to back and side to
side. Nail legs to studs. DO NOT BEND LEGS as this will put the
entire unit into a bind and cause expansion noises. See Figure 8-A.
STEP 8.
A drip leg and a manual valve equipped with a 1/8 N.P.T. plugged
tapping accessible for test gauge connection should be installed
immediately upstream of the gas supply connection to the
appliance. Some codes and ordinances require that the manual
valve be located outside the appliance.
STEP 9.
Make gas connection using connector the same size as gas
connection of furnace. CHECK ALL CONNECTIONS FOR GAS LEAKS
WITH LEAK DETECTOR SOLUTION. DO NOT USE OPEN FLAME.
FIG. 8-B
Burner Shelf
Page 10
Failure to locate the
1018454-E