Fayat DYNAPAC MF2500CS Utilisation Et Entretien page 244

Table des Matières

Publicité

Fault
SPN
FMI
Code
3137
5019
4
3138
5019
2
3139
3667
3
3141
3667
4
3142
4360
3
3143
4360
4
3144
4360
2
3146
4363
3
3147
4363
4
3148
4363
2
3151
4794
31
3152
4809
3
3153
4809
4
3154
4809
2
3155
4810
3
D 23 64
Diesel Engine Failure-Codes chart
SPN
Lamp
Description
Engine Exhaust
Amber
Gas Recirculation
1 Outlet Pressure
Engine Exhaust
Amber
Gas Recirculation
1 Outlet Pressure
Engine Air
Amber
Shutoff Status
Engine Air
Amber
Shutoff Status
Aftertreatment 1
SCR Catalyst
Amber
Intake Gas
Temperature
Aftertreatment 1
SCR Catalyst
Amber
Intake Gas
Temperature
Aftertreatment 1
SCR Catalyst
Amber
Intake Gas
Temperature
Aftertreatment 1
SCR Catalyst
Amber
Outlet Gas
Temperature
Aftertreatment 1
SCR Catalyst
Amber
Outlet Gas
Temperature
Aftertreatment 1
Amber
SCR Catalyst Outlet
Gas Temperature
Amber
Aftertreatment
Warm Up Diesel
Amber
Oxidation
Catalyst Intake
Temperature
Aftertreatment
Warm Up Diesel
Amber
Oxidation Catalyst
Intake Temperature
Aftertreatment
Warm Up Diesel
Amber
Oxidation Catalyst
Intake Temperature
Aftertreatment
Warm Up Diesel
Amber
Oxidation
Catalyst Outlet
Temperature
Cumins Description
Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit -
Voltage below normal, or shorted to
low source
Engine Exhaust Gas Recirculation
Outlet Pressure - Data erratic, intermittent or incorrect
Engine Air Shutoff Circuit - Voltage
above normal, or shorted to high source
Engine Air Shutoff Circuit - Voltage
below normal, or shorted to low source
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit - Voltage above normal, or shorted to
high source
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit - Voltage below normal, or shorted to
low source
Aftertreatment 1 SCR Intake Temperature Sensor - Data erratic, inter-
mittent or incorrect
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit - Voltage above normal, or shorted to
high source
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit - Voltage below normal, or shorted to
low source
Aftertreatment 1 SCR Outlet Temperature Sensor - Data erratic, inter-
mittent or incorrect
Aftertreatment 1 SCR Catalyst System Missing - Condition Exists
Aftertreatment Warm Up Diesel Oxidation Catalyst Intake Tempera-
ture Sensor Circuit - Voltage above normal
Aftertreatment Warm Up Diesel Oxidation Catalyst Intake Tempera-
ture Sensor Circuit - Voltage below normal
Aftertreatment Warm Up Diesel Oxidation Catalyst Intake Tempera-
ture - Data erratic, intermittent or incorrect
Aftertreatment Warm Up Diesel Oxidation Catalyst Outlet Tempera-
ture Sensor Circuit - Voltage above normal