Configuration Of The Outputs - Marklin Digital m83 Manuel D'instructions

Masquer les pouces Voir aussi pour m83:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Configuration of the Outputs

(For switching functions, see page 22)
CV
Meaning
112 POM Switching Function Turnout 1, red
113 POM Pulse Width
114 POM Period
115 POM Switching Function Turnout 1, green
116 POM Pulse Width
117 POM Period
118 POM Switching Function Turnout 2, red
119 POM Pulse Width
120 POM Period
121 POM Switching Function Turnout 2, green
122 POM Pulse Width
123 POM Period
124 POM Switching Function Turnout 3, red
125 POM Pulse Width
126 POM Period
127 POM Switching Function Turnout 3, green
128 POM Pulse Width
129 POM Period
20
Value
Comment
0 – 18
Switches the "red" output for the first turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "green" output for the first turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "red" output for the second turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "green" output for the second turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "red" output for the third turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "green" output for the third turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.