CV
Meaning
130 POM Switching Function Turnout 4, red
131 POM Pulse Width
132 POM Period
133 POM Switching Function Turnout 4, green
134 POM Pulse Width
135 POM Period
We recommend the following pulse widths und periods for our turnout mechanisms:
C Track turnout: 30%, 250 milliseconds
K Track turnout: 75%, 500 milliseconds
M Track turnout: 75%, 1000 milliseconds
Automatic Turnout Circuits (CV 34 & CV 35)
Value Name
0
2 turnouts
1
Three-way turnout
2
Double slip switch
Value
Comment
0 – 18
Switches the "red" output for the fourth turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
0 – 18
Switches the "green" output for the fourth turnout
0 – 255
255 = 100 %
0 – 255
Time interval between the pauses; 1 = 0.05 sec.
Comment
Two outputs, one for each turnout, are switched in turn
4 outputs are linked together for a three-way turnout with 2 mechanisms
4 outputs are linked together for a double slip switch with 2 mechanisms
21