In heating mode (
h
), the water temperature set point can
also be weather dependent (icon
This means that the controller calculates the water
temperature set point based on the outdoor temperature.
In this case, instead of showing the water temperature set
point, the controller shows the "shift value" which can be
set by the user. This shift value is the temperature
difference between the temperature set point calculated by
the controller and the real set point. E.g. a positive shift
value means that the real temperature set point will be
higher than the calculated set point.
3
Switch on the unit by pushing the
The operation LED
0
lights up.
When the unit is connected to an external room
thermostat, buttons
=
icon
e
is shown. In this case, the external room
thermostat switches the unit on or off and determines the
operation mode (space heating or space cooling).
Selection and setting of domestic water heating (
1
Use the
v
button to activate domestic water heating (
Icon
w
appears on the display.
2
Use the
wi
or
wj
temperature set point and subsequently, to set the correct
temperature.
The actual temperature set point only appears on the display
after pressing one of the buttons
pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating: 30°C to 78°C
3
Press the
v
button to deactivate domestic water heating (
Icon
w
disappears from the display.
Remark that pushing the
the domestic water heating. Domestic water heating is only
switched on or off by means of the
Selecting powerful domestic water heating operation
1
Press
v
for 5 seconds to activate powerful domestic water
heating operation.
Icons
w
and
m
start flashing.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (
s
1
Use the
button to activate quiet mode operation (
Icon
s
appears on the display.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 10), the
s
Selecting weather dependent set point operation (only in
heating mode)
1
Press the
ba
button to select weather dependent set point
operation.
Icon
a
appears on the display as well as the shift value. The
shift value is not shown in case it is 0.
2
Use the
bi
and
bj
buttons to set the shift value.
Range for the shift value: –5°C to +5°C
RKHBH/X008BA
Indoor unit for air to water heat pump system and options
4PW54225-1
a
is shown).
y
button.
and
y
are not operable and the
w
)
w
).
button to display the actual
wi
or
wj
. If no button is
w
y
button has no influence on
v
button.
s
)
s
).
button will not be operable.
Displaying actual temperatures
1
Push the
ba
button for 5 seconds.
The
b
icon and the outgoing water temperature are displayed.
The icons
l
and
=
2
Use the
pi
and
The outdoor temperature (
The domestic hot water tank temperature (
flashing).
The outgoing water temperature (
If no button is pressed for 5 seconds, the controller leaves the
display mode.

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.
The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to "Manual operation" on page 5). The schedule timer will regain
control over the installation as soon as the next programmed
command of the schedule timer occurs.
The schedule timer is enabled (
not displayed), by pressing the
Only use the
schedule timer. The schedule timer overrules the
button. The
timer until the next programmed action.
If the auto restart function is disabled, the schedule
timer will not be activated when power returns to the
unit after a power supply failure. Press the
to enable the schedule timer again.
).
When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure.
It is therefore recommended to leave the auto restart
function enabled.
The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to "Setting the clock" on page 5.
Manually adjust the clock for summertime and
wintertime. Refer to "Setting the clock" on page 5.
A power failure exceeding 2 hours will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to "Setting the clock" on page 5 to adjust the clock
and the day of the week.
The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.
To set up the SCHEDULE TIMER refer to chapter "Programming and
consulting the schedule timer" on page 7.
What can the schedule timer do?
The schedule timer allows the programming of:
1.
Space heating and space cooling (refer to "Programming space
heating or space cooling" on page 8)
Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.
NOTE
When the unit is connected to an external room
thermostat, the schedule timer for space heating and
space cooling is overruled by the external room
thermostat.
are flashing.
pj
buttons to display:
u
icon is flashing).
=
are flashing).
p
icon displayed) or disabled (
pr
button.
pr
button to enable or disable the
y
button only overrules the schedule
Operation manual
w
icon is
p
icon
y
pr
button