1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
For your safe use in winter, it's strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
Breaker
Fuse
Power Cord(mm
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
Fuse
Breaker
MODEL
INOA 06
Rated Current
10.5
A
Rated Residual
Action Current
mA
A
10.5
2
)
3×1.5
2
3×0.5
)
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
INOA 08
INOA 12
12.0
16.0
30
30
30
12.0
16.0
3×2.5
3×2.5
3×0.5
3×0.5
- 11 -
For installers and professionals
INOA 14
INOA 18
21.0
25.0
30
30
21.0
25.0
3×4
3×6
3×0.5
3×0.5
>
10m, wire diameter must be