Size(mm)
Model
Inoa 06
Inoa 08
Inoa 12
Inoa 14
Inoa 18
2.2.2. Heat pump installation.
① The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust
treated;
② The heat pump needs a water pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
③ When the heat pump is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please insert the drainage tube(accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
2.2.3. Wiring & protecting devices and cable specification
① Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
② Well earth the heat pump.
③ Wiring must be connected by a professional technician according to the circuit diagram.
④ Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
⑤ The layout of power cable and signal cable should be orderly and not affecting each
other.
Name
A
B
315
590
315
590
395
590
395
590
395
720
※ Above data is subject to modification without notice.
For installers and professionals
C
D
E
312
340
961
312
340
961
392
420
961
392
420
961
392
420
1092
- 10 -
F
G
H
250
74
658
340
74
658
390
74
658
460
74
758
620
74
958