3. Technical specification
Model
Advised pool volume (m
Working air temp (℃)
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
COP
COP at 50% capacity
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
COP
COP at 50% capacity
Rated input power(kW) at air 15℃
Rated input current (A) at air 15℃
Max input current(A)
Power supply
Advised water flux
Sound pressure 1m dB(A)
Sound pressure 10m dB(A)
Water pipe in-out Spec (mm)
Net Dimension LxWxH (mm)
Net Weight
(kg)
1. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration
system running at least 15 hours a day
2. Related parameters are subject to adjustment periodically for technical improvement without further
notice. For details please refer to nameplate.
INOA 06
3
20~40
)
8.0
14.7~7.0
10.6
5.8
7.3~4.8
6.5
0.16~1.2
0.7~5.2
8.0
2~4
(m³/h)
38.8~48.2
18.8~28.2
961×340×658
45
INOA 08
INOA 12
30~55
40~75
-7~43
12.0
17.3
14.8~5.7
15.5~5.9
10.3
10.8
8.0
11.4
7.4~4.3
7.8~4.3
6.2
6.3
0.24~1.8
0.3~2.6
1.04~7.8
1.3~11.3
10.0
13.5
230V/1 Ph/50Hz
4~6
6.5~8.5
42.1~50.7
43.1~53.8
22.1~30.7
23.1~33.8
50
961×340×658
961×420×658
50
63
- 7 -
For users
INOA 14
INOA 18
50~95
65~120
21.0
27.3
15.2~5.7
15.3~6.2
10.5
11.0
14.3
18.0
7.7~4.2
8.1~4.6
6.2
6.7
0.36~3.3
0.53~3.8
1.57~14.3
2.3~16.5
17.5
21.0
8~10
10~12
40.9~54.2
43.5~54.9
20.9~34.2
23.5~34.9
961×420×758
1092×420×958
68
90