5
Operation
TIMER button
Used to initiate the Auto on start time and Auto off stop time program, in conjuction with the
+ & - buttons, The timer on/off indicator light illuminates under the timer on/off settings.
MODE button
Selects the appropriate operating mode. Each time you press the button, a mode is selected in a
sequence that goes from Auto, Cool, Dry, Fan and Heat (cooling only models without). The mode
indicator light illuminates under the different mode settings.
Up (+) and Down (-) buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C increments in a range of 17°C to
30°C or the Timer setting in a range of 0-24hrs.
C
Note: The control is capable of displaying temperature in degrees Celsius. To convert
from one to the other, press and hold the Up and Down buttons at the same time for
3 seconds.
FAN
Control the fan speed. Press to select the fan speed in four steps-Low, Med, High and Auto. The fan
speed indicator light illuminates under different fan settings. When select Auto fan speed, all the fan
indicator lights turn dark.
SLEEP button
Used to initiate the Sleep operation.
Power button
Power switch on/off.
LED display
Shows the set temperature in °C and the Auto-timer settings. While on Dry and Fan modes, it shows
the room temperature.
Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
P1-Bottom tray is full--Connect the drain hose and drain the collected water away. If protection
repeats, call for service.
32 / 276 EN
Local air conditioner / Instruction Manual