Napoleon HIGH COUNTRY 3000H Manuel D'installation Et D'opération page 32

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

fi nishing
EN
Blower Fan
Connections
- Removing the
junction box cover
on the blower
exposes 3 coloured
wires:
One black wire
- connects to power
"L2" (neutral lead).
One green wire
- connects to
ground.
One white wire
- connects to the
fan-speed control, rheostat, or wall switch, or thermostat.
VENT CONNECTION
D. Connect the 6" (152mm) liner to the 6"(152mm) appliance collar and blower collars. Secure using 3 screws on
each end and seal with caulking. Liner stretches to a maximum of 10' (3m).
GRILL AND FILTER INSTALLATION
E. Insert the fi lter into the grill. Foam gasket (1/2" [13mm] weather stripping) between the grill and blower housing
is recommended, but not supplied. The blower fi lter is washable. The bottom lip of the grill latches over the
bottom lip of the housing. Use two screws to secure the top of the grill to the facing.
note:
For complete installation instructions, refer to the blower kit.
32
W415-1761 / B / 12.21.18
Pressure
Switch
Thermodisc
Appliance
Factory Wiring in Appliance
Junction Box
INSTALL THE KB35 AND
BY-PASS SWITCHES IN A
CONVENIENT LOCATION
Main Power Supply
Neutral
L1
L1
By-Pass
By-Pass
(Summer Switch)
By-Pass
Not supplied
Blower
FILTER
ALLOW FOR
THICKNESS
GRILL
OF FINISHING
MATERIAL
Fan-speed Control
(Rheostat [variable
speed switch]) or wall
switch or thermostat
(Not supplied)
Field installed
Connection Point
FAN

Publicité

Table des Matières
loading

Table des Matières