Les langues disponibles

5.
Remove the nozzle from the end
of the wand with the 2 mm hex
key provided (see Fig.11).
Fig. 11
6.
Clean the nozzle using the nozzle
cleaner provided or a straightened
paper clip. Insert into the nozzle
end and work back and forth until
obstruction is removed
(see Fig. 12).
Fig. 12
7.
Direct water supply into nozzle
end to backflush loosened
particles for 30 seconds
(see Fig. 13).
Fig. 13
A04196
8.
Reconnect spark plug wire
9.
Reassemble the nozzle to the
wand. Tighten securely to prevent
leaks.
10. Reconnect wand to gun and turn
on water supply.
11. Start pressure washer and place
wand into high pressure setting to
test.
HOW TO CLEAN THE WATER
INLET FILTER
This screen filter should be checked
periodically and cleaned if necessary.
1.
Remove filter
by grasping end
and removing it
from water inlet
of pump
(see Fig. 14).
2.
Clean filter by
flushing it with water on both
sides.
3.
Re-insert filter into water inlet of
pump. NOTE: Do not operate
pressure washer without filter
properly installed.