InSTALLATIon—GAS ConneCTIonS
ProvIDe ADequATe
1
GAS SuPPLY
This cooktop is designed to operate on natural gas
at 4" of water column manifold pressure and 7" of
water column (W.C.) supply pressure. It is shipped
from the factory set for natural gas. The convertible
pressure regulator supplied with the unit must
be connected in series with the manifold of the
cooktop and must remain in series with the supply
line regardless of whether natural or L.P. gas is
being used.
FOR PROPER OPERATION, THE MAXIMUM INLET
PRESSURE TO THE REGULATOR MUST BE NO MORE
THAN 14" OF WATER COLUMN PRESSURE. For
checking the regulator, the inlet pressure must
be at least 1" W.C.. (or 3.4 KPA) greater than the
regulator output setting. If the regulator is set for 4"
W.C. of water column pressure, the inlet pressure
must be at least 5" W.C. If the regulator is set for
10" W.C., the inlet pressure must be at least 11"
W.C.. The gas supply line to the cooktop should be
1/2" or 3/4" pipe.
2 InSTALL reGuLATor
NEVER REUSE OLD CONNECTORS WHEN
INSTALLING THIS COOKTOP.
WArnInG:
flexible connectors. The use of old flexible
connectors can cause gas leaks and personal
injury. Always use new flexible connectors when
installing a gas appliance.
Screw a section of pipe onto
the inlet end of the pressure
regulator and install the
coupling.
To reduce the likelihood of gas leaks, apply teflon
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
Installation Instructions
Never reuse old
Pressure
Regulator
Coupling
3 InSTALL reGuLATor onTo
Burner Box BoTToM
Screw the regulator
onto
the burner box
bottom pipe
connection.
Make sure the
top of the regulator
is
facing towards the
cabinet front, easily
accessible through
the cabinet doors.
CoMPLeTe ConneCTIon WITH A
4
CouPLInG
Complete the
connection between
the regulator pipe
coupling and
the shut-off valve.
6
Pressure
Regulator
Coupling
Shut-Off
Electrical
Valve
Outlet 12"
Below
Countertop
Pressure
Regulator
Coupling
Shut-Off
Electrical
Valve
Outlet 12"
Below
Countertop