Switch (C) to adjust the power 1250W = heat with low power consumption, turns
-
on in pos.(1250) or turns off in pos.(●).
Switch (B+C) to adjust the power 2000W = immediate heat, turns on in
-
pos.(750+1250/2000W) or turned off in pos.(●).
The thermostat (D) regulates the appliance based on the surrounding ambient
-
temperature: it heats continuously until the set temperature is reached, and then
it heats only when the temperature decreases and for the period of time needed
to bring it back up to the set temperature.Use the respective knob: if turned fully
in an anticlockwise direction, the fan heater stays off (MIN), if fully turned
clockwise it is set to the maximum temperature (MAX); the heater runs at intervals
when set to the settings in between.
To operate the heater: check that the thermostat knob is in pos."MIN", insert the plug
into the socket and select the desired functions described above.
To turn off the appliance, turn the thermostat knob to pos."MIN" and of the selectors
in pos.(●)and remove the plug from the socket.
Model with 24h timer, switches and with room thermostat regulation (type HC505)
The heater is equipped with the following adjustment devices:
Switch (A) to turn on the fan (turbo function), turns on in pos.(
-
pos.(●).
Switch (B) to adjust the power 750W = heat with low power consumption, turns on
-
in pos.(750) or turns off in pos.(●).
Switch (C) to adjust the power 1250W = heat with low power consumption, turns
-
on in pos.(1250) or turns off in pos.(●).
Switch (B+C) to adjust the power 2000W = immediate heat, turns on in
-
pos.(750+1250/2000W) or turned off in pos.(●).
The thermostat (D) regulates the appliance based on the surrounding ambient
-
temperature: it heats continuously until the set temperature is reached, and then
it heats only when the temperature decreases and for the period of time needed
to bring it back up to the set temperature.Use the respective knob: if turned fully
in an anticlockwise direction, the fan heater stays off (MIN), if fully turned
clockwise it is set to the maximum temperature (MAX); the heater runs at intervals
when set to the settings in between.
- Slider switch (F): when the index is in position
"I" the appliance works, but the timer is
excluded,
in position "
" the timer is active, in pos."0" the appliance is off.
24H timer (E): allows to adjust during the 24
-
hours, "on" and "off" periods of the fan heater,
and to repeat them systematically every day; it
is active when the slider switch (F) located
below is in correspondence with the symbol"
".When using the timer, first:
17