1
Wa ll moU n t in G
install the chronothermostat at 1.5 meters
above the floor level, far from kitchen ranges,
sources of heat, windows and doors.
make sure the base is properly secured to a
level surface, without straining.
2
e l e ct r ic connections
connect terminals 1 - 2 to the heating system
with two wires thus replacing the traditional
thermostat at any time and without adding
further connections. When the ambient
temperature increases, the relay will open
terminals 1 - 2 and will close terminals 1-4.
terminal 4 is free and it may be used for
signalling or other purposes, as required.
Phone activators ct3m and ct3ma: connect
the 2 wires of the rF receiver to the terminals
1-2-3, as shown in the picture. to manage
the remote control, refer to the "controls"
paragraph about c55/75 in the instruction
manual of the phone activators ct3m and
ct3ma.
3
s e l e ct
t H e "o FF" oP eratin G mo De
When in oFF mode, intellitherm may be set
to keep a fix temperature of 5°c in order to
protect the system from the risk of freezing.
this selection shall be made when installing
the device and before fitting the batteries.
n.B. if at any time after installation this
selection has to be changed, intellitherm shall
be reset and reprogrammed.
4
F i t t He cH r onotH ermos tat Bo DY on
t H e B as e
5
F i t t i nG anD r eP laceinG
t He Batt e ri es
Fit two high-quality long life alkaline aa 1.5
V batteries respecting the specified bias.
Batteries could last approximately two years:
when batteries begin to run down the battery
symbol on the display will start to flash.
should batteries be not replaced within 15 days,
intellitherm c57ct will turn off automatically
and the display will only show the word oFF.
6
s e t c Urr e n t time an D DaY
[ s e e p ic tu re on t he right]
6
B 60 mm
a 83,5 mm
4 2
1
4
3 1 2
to insert batteries remove the cover pulling it frontaly
intellitherm
i n s t a l l a t i o n
to separate the body from
the base for the fitting,
remove the batteries cover
and loosen from top the two
screwes, turning the body
downwards.
a
for flush-mounting
box, 503 type (three
modules)
B
for round
flush-mounting boxes
connection to ct3m
and ct3ma
3
1
2 c57ct
ct3m
ct3ma
to be installed
!
b y q u a l i f i e d
personnel only!
to set the antiFreeZe 5°c protection
move the dip switch HiGH.
to switch the system completely oFF,
move the dip switch DoWn.
-
+
-
1.5V
'aa'
'aa'
time and day setting keys
e n g l i s h
3
2
1
4
2
1
+
1.5V
AUTO