Installation Instructions
®
LUX-top
SDH-Z II
for attaching roofers' ladders / duck runs and for attaching the personal protective equipment
against falls from a height
Introduction:
Before installing the anchor construction the load-bearing capacity of the roof structure must be checked.
The technical building regulations must be complied with.
Only original parts of the anchor point system may be used.
Note the installation and safety information in the user instructions.
LUX – top
Fix the
cross-lathe in the middle of the rafters
(min. 6/14 cm; min. strength class C 24 to
DIN EN 338) as shown in the following
installation
sketch
woodscrews 8.0 x
predrilling).
NOTE:
Ensure that the
SDH-Z II
is positioned so that it fits into
the joins of the roofing.
In the case of tiles with sidelock and
headlock the welt must be ground out a
little in the relevant place.
IF THE REQUIRED MINIMUM ENGANGEMENT LENGTH IS NOT ENSURED DUE TO THE
ROOF CONSTRUCTION FOUND ON SITE, LONGER WOODSCREWS MUST REQUESTED
FROM THE MANUFACTURER!
ST QUADRAT Fall Protection S.A. – Ihr kompetenter Partner für Absturzsicherungen – www.lux-top-absturzsicherungen.de
roof safety hook
®
SDH-Z II
onto the
using
the
three
L
mm supplied (without
®
LUX – top
Depending on the dimensions of the roof lathing,
level differences are to be balanced out by
inserting spacers underneath (recommendation:
Euroklick Type 2).
Screw length
L
the existing roof structure.
Minimum engagement length
in the load-bearing structural member
(rafters) = 130 mm
Minimum rafter cross-section: 6 / 14 cm
Seite 2
is specified depending on
01/15