Timer mode

3.7
The Timer mode allows you to adjust, the
temperature and the duration for a special time.
This function can be used when you stay at home
for several days, or if you want to override the
program for some time (reception...)
- You can first adjust, the duration in hours "H" if
below 24H, then in day "d" with (-) or (+), press
(OK) to validate. (Adjustable 1 Hour to 99 days)
- In a second time, you can adjust the desired
setting temperature with (-) or (+), press (OK) to
start the function. (Default value 22°C)
The
logo will be blinks and the number of hours
/days left is displayed until the end of the period.
If you want to stop the Timer function before the
end, set the duration period to "no" with (-) key.
5

Parameter's menu

Your thermostat has a parameter's menu, in order
to enter in this menu, press and maintain the edition
key ( ) during 5sec. Then parameter menu will
appear and first parameter screen will be displayed:
Now you can select a parameter which must be
adjusted with the navigation keys (◄) or (►), once
the parameter chosen, toggle the value with the
(OK) key, modify it with (-) or (+) and confirm your
adjustment with (OK).
To leave the parameter menu, choose the
parameter « End » and press (OK).
4

Special function

Keyboards lock Function

4.1
Use this function to prevent all change of your
settings (In a child room, public area...)
- To activate the Key lock function, first press
maintain the escape key (
simultaneously on the edition key ( ).
- The "
" logo will be displayed on the screen.
- Repeat the same procedure to unlock the key
board.

Information

4.2
With this function You can quickly view all currents
temperatures of the probe sensors connected to
your thermostat (Floor, external or outside sensor)
by several presses on the escape key (
"Scroll function" is only available in the main screen.
You can view:
31
Default value & other possibilities
dEG: Unit of the temperatures displayed
01
°C Celsius
°F Fahrenheit
__:__ Selection of the Time clock unit
02
24H (24:00)
12H (12:00 AM /PM)
dst: Daylight Summer time change Summer<->Winter
03
YES automatic change according to date.
no
no daylight summer time automatic change.
AirC: Calibration of the internal probe
04
The calibration must be done after 1 day working with
the same setting temperature in accordance with the
following description:
Put a thermometer in the room at 1.5M distance from
the floor (like the thermostat) and check the real
temperature in the room after 1 hour.
When you enter on the calibration parameter "no" is
displayed on the right to indicate no calibration has
made.
To enter the value shown on the thermometer, use the
(-) or (+) keys to enter the real value. Then, press (Ok)
34
) and then press
).This
32
05
06
07
35
- The current setting temperature followed by the
thermostat.
- The ambient temperature
- If external sensor is connected:
The Floor temperature if it is used as floor sensor.
The outside temperature if it used as outside
sensor.
If Parameter "SenS" is set on "Air", the external
sensor will be used as an outside temperature
sensor
to confirm.
The message "Yes" should be displayed; the value will
be stored in the internal memory.
If you need to erase a calibration press on the escape
key (
).
The old value will be erased and the message "no" will
be displayed.
* Pay attention:
Only the heating element driven by the thermostat must
be used during the complete step of the calibration.
OutC , AMbC , FlrC: Calibration of the external
wired probe
Same calibration method as described in parameter
"04 AirC" above.
HG: Anti-freeze temperature used in Holiday mode
Default value 10°C.
Use the (-) or (+) keys to change the anti-freeze setting
temperature. Then press (Ok) to confirm.
ITCS: YES, no
The Intelligent Temperature Control System will
activate your installation in advance (2 hours
maximum) to assure the desired temperature at the
33