1.
General
E
The following instructions must be followed in full
to ensure correct use of this fluid level sensor.
2.
Function
HYDAC fluid level sensors monitor the fluid level
in a hydraulic tank.
The switching signals (max. switching current 0.2 A)
can be used as a warning message to regulate
the fluid level or directly in a PLC control.
On the dual switching circuit, both opening and
closing functions can be used for control
or evaluation.
FSK-2SP
When the maximum or minimum level is reached,
this state is transmitted via electrical switching
signals.
FSKV
When the adjustable maximum or minimum level
is reached, this state is transmitted via electrical
switching signals.
In addition, variable advance warning points
can be pre-set.
Visual indication of the fluid level is also guaranteed.
10
Tank fluid level
FSK - W
3.
Technical specifications
3.1
DESIGNATION & SYMBOL
3.2
TYPE OF CONSTRUCTION
The units are designed to be mounted directly
on to the fluid tank.
3.3
MOUNTING POSITION
Threaded holes M12 or M10 on the side of the tank
alternatively, clearance holes Ø 13 or Ø 11.
3.4
MOUNTING POSITION
Vertically on the tank wall
(connection plug on left or right of the FSK housing)
3.5
WEIGHTS
FSK 127 - 0.24 kg
FSKV 127 - 0.29 kg
FSK 176 - 0.27 kg
FSKV 176 - 0.32 kg
FSK 254 - 0.30 kg
FSKV 254 - 0.37 kg
FSK 381 - 0.35 kg
FSKV 381 - 0.46 kg
3.6
AMBIENT TEMPERATURE
min. -20 ºC
max. +80 ºC
3.7
MATERIALS
End caps: Aluminium
Tube: Glass
Housing: Aluminium (FSK-2SP),
stainless steel (FSKV)
Seals: Perbunan (NBR)
Bolts and nuts: Steel (zinc-plated)
E
W – N/O or N/C
(dual switching unit)
11