Situation
Cleaner moves slowly or not at all.
Cleans only perimeter of pool.
Cleaner hovers in one area
with hose fully extended.
Cleaner turns in clockwise circles
only and only covers one section of pool.
Oscillator runs too fast.
Hose keeps coiling up.
Pool not completely clean in four hours.
Cleaner flips on its side when
pump stops.
Hose comes loose when pump stops.
Cleaner sticks to pool bottom or
pool main drain.
If you have any questions, please call 1-800-831-7133
Troubleshooting
Solution
• Backwash and clean filter. Empty all baskets.
• Clear debris from oscillator or hose.
• If hoses from skimmer to filter and back to pool are less than
1-1/2" diameter, replace with 1-1/2" hoses.
• Pump in filtration system may be too small. Consult pool
professional.
• If your pool has a main drain (floor drain), close it during
cleaner operation.
• Make sure vacuum regulator is installed.
• Set brush ring adjuster to a higher number.
• Hose is too short. It should be approximately 5-8' longer than
the full length of the pool. Buy an extension hose from your
dealer to give adequate length.
• Set brush ring adjuster to a lower number.
• Make sure vacuum regulator is installed.
(the regulator marked "50" will slow it the most).
• If your system has a return valve, gradually close it until
oscillator runs at the desired speed.
• For best results, when hose is not in use, store it flat and straight.
• Lay hose out in the sun (flat and straight) for a few hours.
• Hose is too long; remove 8' section.
• Any cleaner may miss a spot. Spot clean pool by attaching a
vac-pole (telepole) to cleaner and steering it (see Page 5).
• Try different brush ring adjuster settings (0-4) until the cleaner
gives the desired results.
• The cleaner was not designed to work under all solar covers.
• Strong winds may interfere with complete cleaner coverage.
• This is normal if filter system develops a backpressure surge
when the pump stops. The cleaner will right itself when system
is restarted.
• Use reducer cone in skimmer.
• Install diaphragm marked "50" in vacuum regulator.
• Check inner brush ring for excessive wear.
6