2.3. Load limiter electrical connection
a) Correctly secure the electrical cable of the load limiter up to the control cabinet.
b) Connect the control circuit contact wires as instructed in § 2.4.
limiter; in this way, an overload situation will be detected when the contacts open.
machine in the event of an accidental interruption of the link between the load limiter
and the control circuit.
situations where the operator warning system has been triggered subsequent to
cross-over of one of the thresholds.
GB
2.4. Connection diagram
S1
Vert
Green
NF
NC
Brun
Brown
NO
Blanc
White
Micro switch interrupting capacity: 4 A / 230 VAC.
Reset hysteresis: variation of 200 daN on strand.
Only one safety feature should be managed by one of the NC contacts of the load
Applying this condition will also ensure a positive safety function for the lifting
The NO contacts are intended for management of slack cable situations and/or
Jaune / Vert
Yellow/Green
Bleu
Blue
Grey
Rose
Pink