2. INSTALLATION OF LOAD LIMITER HF 31/1/A2
DANGER: Product must be installed by a qualified technician.
2.1. Parts list of load limiter and its environment
GB
1 Connecting cable
2 Cable gland
3 Cotter pin
4 Zinc-plated washer
5 Nameplate
6 Adjustment screw and
locknut
7 Adjustment screw and
locknut
2.2. Installing the load limiter on the wire rope
a) Position the compression pin (14) in accordance with the force in the wire rope.
8 Protective rubber piece
9 Deformation cell
10 Lower guide
11 Fixed half-clamp
12 Mounting screw
13 Mobile half-clamp
14 Compression pin
15 Upper guide
16 Pull wire rope
0 POSITION
POSITION 0
For a 5 to 6 mm wire rope
Pour un câble de 5 à 8 mm et
and loads of between
des charges comprises entre
200 and 900 kg.
200 kg et 900 daN.
POSITION 1
1 POSITION
For a 9 to 13 mm wire rope
Pour un câble de 9 à 13 mm et
and loads of between
des charges comprises entre
200 and 1 850 kg.
200 kg et 1850 daN.
2 POSITION
POSITION 2
For a 14 to 16 mm wire
Pour un câble de 14 à 16 mm et
rope and loads of between
des charges comprises entre
200 and 3 200 kg.
200 kg et 3200 daN.
6
17 Winch
18 Pulley block
19 Hook
20 Sensor
21 Fixed point
IMPORTANT
Before applying a load and if
no factory presetting has been
requested,
make
sure
adjustment screws are un -
screwed to the maximum.
Failure to do so will result in risk
of destruction of micro-switches
by crushing.
If the wire rope diameter does
not correspond to the load
range, the load information will
be the decisive information.
the