Note: In every PlaneLok mode the laser continues to servo to the receiver's signals.
Any loss of signal over an extended period of time (1 minute) causes the laser to go
into the HI-alert condition (beam turns off, rotor stops and a warning message occurs
at the RC402N LCD). PlaneLok mode can be reactivated after the HI-alert condition
has been deleted with the E button.
Exiting of PlaneLok can be done by pressing the Manual button or any HL760/HL760U button where the unit
goes always back to automatic mode.
Line Scan (Vertical Setup)
When setting up the unit vertical, Line Scan centers the rotor horizontally and can be used to align the laser
reference to a desired line position.
Press and release the M button at the Standard Display and select >>Line Scan<<.
Press and release button E to start Line Scan.
The rotor checks the limits of the X- axis (LS is flashing) and stops at the center position.
Pressing the Manual button stops the movement and changes the unit into manual mode.
Corrections left and right can be done using Left/Right arrow buttons.
Press and release the Manual button to change the unit back to full automatic mode.
Beam Plunge (Vertical Setup)
Beam Plunge centers the rotor vertically and can be used to align the plumb beam to a
desired vertical position, e.g., when doing Interior layout.
Press and release the M button at the Standard Display and select >>Beam Plunge<<.
Pressing and releasing button E activates the Beam Plunge mode while the rotor checks
the limits of the Y- axis and switches back to automatic mode at the center position.
Pressing the Manual button stops the movement and changes the unit into manual mode.
Corrections up and down can be done using button Up/Down; for left/right corrections use button Left/Right.
Press and release the Manual button to change the unit back to full automatic mode.
24