Failure
Poorly operating or malfunctioning
remote control.
Fan fails to rotate.
Fan works but the air cleaner
functions poorly or not at all.
Crackling sound from the
ElectroMax.
The air cleaner cannot be
controlled manually.
led blinks.
STANDBY
•••• and • leds blink.
The fan speed does not increase
when using the AirMonitor.
The AirMonitor starts while the
atmosphere is apparently clean.
Smells are no longer adsorbed.
No pleasant fragrance.
Fan works but no UV-lights.
7

TECHNICAL SPECIFICATIONS

VisionAir
Dimensions
630 x 620 x 290
mm
Max. built-in height
210 mm
Weight
16,5 kg
Power consumption
22 W
UV lighting
EN - 9
0508082010/100504/D
Possible cause
(Nearly) exhausted battery.
Defective fan.
Faulty hardware and/or software.
One or more filters are polluted.
Outlet grids are closed.
Dirt in the ElectroMax filter causes a short-circuit
(
led blinks)
STANDBY
ElectroMax filter dirty or wet.
Missing PreFilter.
The distributor has blocked the control.
Dirt in the ElectroMax filter causes a short-circuit.
Short-circuit in the ElectroMax filter by a broken
ionisation wire and/or bent collector lamella.
Unit is in PROGRAM mode.
The X-Changer indicates that the filters are
clogged.
The distributor has limited the fan speed in the
software.
Sensor reacts to, for instance, a high or low
humidity or fumes from cleaning agents.
Sensitivity setting of AirMonitor unsatisfactory.
Activated carbon or OdourFree filter is saturated.
FreeBreeze not switched on.
FreeBreeze cartridges are spent.
Defective UV-lights.
AirMonitor analysing the air.
1
2
VisionAir
630 x 1050 x 290
mm
210 mm
32,5 kg
44 W
Solution
Check the red led above the
remote control by pressing any button. Replace the
battery if the led is not activated.
Call in your distributor.
Call in your distributor.
Replace or clean the filters (see section 5).
Open one or more of the outlet grids (see section
4.5).
Clean the ElectroMax filter (see section 5.2.2).
Clean or dry the ElectroMax filter (see section
5.2.2).
Install PreFilter.
Call in your distributor.
Clean the ElectroMax filter (see section 5.2.2).
Call in your distributor.
Push the PROGRAM button on the remote control
once or several times or wait for 1 minute.
Clean the ElectroMax filter (see section 5.2.2).
Call in your distributor.
The sensitivity will adjust itself after some time.
Call in your distributor.
Replace the activated carbon or OdourFree filter
(see section 5.2.3).
Rotate FreeBreeze cartridges anti-clockwise to the
intensity desired (see section 4.4).
Replace FreeBreeze cartridges (see section 5.3).
Call in your distributor.
Wait for 2 minutes and check again.
button on the