FAULTS AND REPAIRS

Repairs may only be carried out by the dealer or authorised persons.
Problem
Air cleaner does not function.
Remote control functions poorly or not
at all.
Fan does not run.
Fan runs, but air cleaner does not clean
or cleans poorly.
EM Blue Line filter (ElectroMax) crackles.
The air cleaner cannot be operated at the
device.
Indicator LED flashes red
Indicator LED flashes blue.
Indicator LED flashes red +
symbol
The air cleaner does not go to a higher
speed when the gas sensor is used.
Gas sensor starts in seemingly clean
rooms.
Air cleaner no longer absorbs harmful
gases or unpleasant odours.
Air cleaner no longer diffuses a pleasant
odour.
11

TECHNICAL SPECIFICATIONS

See Figures 4 and 5 on the illustrations page
VisionAir Blue Line 1
Dimensions
630 x 620 x 290 mm
Installation height
210 mm
Weight
16.5 kg
Consumption of UV lamps 22 W
22
Possible cause
Safety switch does not function.
Mains voltage not connected.
Cable or plug defective.
Hardware/software defective.
Battery (almost) empty.
Fan defective.
Hardware/software defective.
One or more filters soiled.
Air outlet grilles are closed.
Short-circuit in the EM Blue Line filter due to soiling
(STANDBY LED flashes).
EM Blue Line filter (ElectroMax) soiled or damp.
Pre-filter missing.
Operation has been blocked by your dealer.
Short-circuit in the EM Blue Line filter due to soiling.
Short-circuit in the EM Blue Line filter due to broken
ionisation wire and/or bent collector plate.
Device is in PROGRAM mode.
This is the X-Changer indicating that the filters are
soiled.
The fan speed has been limited in the software by
your dealer.
Sensor reacts i.a. to very high or very low humidity or
to gasses from cleaning agents, etc.
Sensitivity of the AirMonitor is not as desired.
Activated carbon filter saturated.
FreeBreeze is not correctly set.
FreeBreeze cartridges have lost their odour.
VisionAir Blue Line 2
630 x 1050 x 290 mm
210 mm
32.5 kg
44 W
Solution
Close the air intake grille properly or consult your dealer.
Connect the mains voltage.
Have the cable or plug replaced by your dealer.
Consult your dealer.
Check the red LED above the • button on the remote
control by pressing any of the buttons. Replace the battery
of the LED does not light up.
Consult your dealer.
Consult your dealer.
Clean or replace the filters (see section 8).
Open one or more air outlet grilles (see section 4.5).
Clean the EM Blue Line filter (see 8.2.2)
Clean the EM Blue Line filter or allow to dry thoroughly
(see 8.2.2).
Install a pre-filter.
Consult your dealer.
Clean the EM Blue Line filter (see 8.2.2).
Consult your dealer.
Switch the device OFF and then ON again.
Clean the ElectroMax filter (see section 8.2.2).
Consult your dealer.
The sensitivity will be gradually adjusted automatically.
Consult your dealer.
Replace the activated carbon filter (see section 8.2.3).
Turn the FreeBreeze cartridges to the left until the desired
intensity is obtained (see section 7.4).
Replace the FreeBreeze cartridges (see section 8.3).