Calibrating The Room Sensor; Changing The Domestic Hot Water Temperature; Selecting The Principal Display - OERTLI RS400 Notice D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

AD257
%
+
%
0
2
4
6
8
10
12
14
16
18
20
MODE
A000852-B
+
MODE
1
2
3
4
5
6
%
0
2
4
6
8
10
12
14
16
18
20
MODE
12/02/2018 - 300020550-001-03
6. To return to the principal display, press the MODE key or wait 20
3.2.3.
1. Measure the room temperature with a thermometer.
2. Press key Cx and Vc simultaneously for 5 seconds.
5"
C002430-B
3. Turn the rotary button to set the room temperature.
22
24
4. To confirm, press the rotary button.
°C
3.2.4.
In the factory, the domestic hot water temperature is set to 55°C. Setting
can be done from 10 to 80°C in steps of 1°C.
To modify the domestic hot water temperature, proceed as follows:
1. Press the MODE and r keys simultaneously for 5 seconds. The 1
5"
A000857-A
2. To modify the setting, turn the rotary button.
3. To return to the principal display, press the MODE key or wait 20
7
22
24
C002542-C
3.2.5.
In the factory, the principal display is set to show the current time and
the outside temperature.
Other settings available:
4 The current time and the room temperature
seconds.

Calibrating the room sensor

The symbol CAL and the current temperature are displayed.
Setting is done in steps of 0.1°C. The correction range is between
+ and -5 °C compared with the temperature displayed.
Changing the domestic hot water
temperature
menu is displayed.
seconds.

Selecting the principal display

3. Operating instructions
EN
39