SCHEMI D'INSERZIONE • WIRING DI GR MS • SCHEM S DE R CCORDEMENT • NSCHLUßBILD
S 1000/232
1N1E
I N P U T
2 5 8
11
1
2
11
5 8
a
b
A
B
S1
L
P1
N
RS 485
33 34 35
+ –
Rx / Tx GND
I N P U T
15 29
4 7
2 5 8 1 11 3 6 9
O U T P U T
M-Bus
34 35
aA
2 5 8
bB
LN
11
LOAD
X
P1
S1
S 1000/246
3-2E (1-3)
I N P U T
11
1 3
2 5 8
2
5
8
a
b
a
b
A
B
A
B
S1
L1
P1
L2
L3
2 5 8
4 7
I N P U T
11
15 29
2 5 8 1 3 6 9
34 35
+ –
Rx / Tx GND
RS 485
33 34 35
M-Bus
O U T P U T
L1
a
L2
A
L3
S1
P1
S1
P1
b
B
a
A
B
X
X
b
LOAD
X
S 1000/245
3-2E (1-2)
I N P U T
11
2 5 8
1
5
8
2
a
b
a
b
A
B
A
B
S1
L1
P1
L2
L3
I N P U T
O U T P U T
Rx / Tx GND
+ –
M-Bus
RS 485
b
A
B
L2
3 6 9
P1
2 5 8 1 11 4 7
P1 S1
S1
B
L1
a
L3
A
2 5 8
b
a
X
X
X
15 29
33 34 35
LOAD
34 35
S 1000/249
3N1E
VOLTAGE
2 5 8 11 1 3
2 5 8 11
a
A
S1
L1
P1
L2
L3
N
a
CURRENT
2 5 8 11
2 5 8 11 1 3 4 6 7 9
15 29
I N P U T
VOLTAGE
O U T P U T
34 35
M-Bus
+ –
Rx / Tx GND
RS 485
33 34 35
L2
A
N
L3
L1
S1
X X X
P1
LOAD
X
X
X
NOT
Negli schemi sono sempre indicate le configurazioni con uscita impulsi e comunicazione RS485 o M-Bus.
Nelle versioni che non prevedono uscita impulsi o comunicazione RS485 o M-Bus non si deve tenere
conto dei relativi collegamenti.
NOTE
Sur les schèmas sont toujours indiquèes les configurations avoc sortie à impulsions et communication
RS485 ou M-Bus. Pour les versions sans sortie à impulsions ou communication RS485 ou M-Bus, on ne
doit pas tenir compte des connexions relatives.
O U T P U T
RS 485
Rx / Tx GND
+ –
3
4
6
7
9
33 34 35
15 29
6
X
LOAD
O U T P U T
RS 485
Rx / Tx GND
+ –
4
6
9
33 34 35
7
15 29
X
X
S1
LOAD
X
P1
O U T P U T
RS 485
Rx / Tx GND
+ –
3
4
9
15 29
33 34 35
6
7
S1
X
X
P1
LOAD
X
I N P U T
O U T P U T
RS 485
CURRENT
Rx / Tx GND
+ –
4 6 7 9
15 29
33 34 35
X
X
X
X X X
LOAD
S 1000/248
3-1E
M-Bus
34 35
2
5
8
a
b
a
b
A
B
A
B
L1
L2
L3
M-Bus
I N P U T
O U T P U T
RS 485
Rx / Tx GND
a
A
b
B
a
A
b
B
L1
L2
2 5 8
2 5 8 1 11 4 7
15 29
X
+ –
33 34 35
3 6 9
34 35
P1
X
S1
L3
X
LOAD
S 1000/247
3-2E (2-3)
M-Bus
34 35
5
8
2
a
b
a
b
A
B
A
B
L1
L2
L3
O U T P U T
I N P U T
b
L1
B
b
a
A
B
A
a
2 5 8
2 5 8 1 11 3 6 9
4 7
33 34 35
Rx / Tx GND
+ –
15 29
S1
RS 485
M-Bus
34 35
L3
L2
X
X
X
LOAD
P1
P1 S1
S 1000/250
3-3E
M-Bus
34 35
2
5
8
a
b
a
b
A
B
A
B
L1
L2
L3
I N P U T
2 5 8 11 1 3 4 6 7 9
CURRENT
2 5 8
VOLTAGE
15 29
M-Bus
RS 485
Rx / Tx GND
O U T P U T
33 34 35
34 35
+ –
L3
L2
A
S1
a
B
P1
b
A
P1
a
L1
b
S1
B
X
X
X
LOAD
P1
S1
S 1000/231
3N3E
M-Bus
34 35
2 5 8 11
a
A
L1
L2
L3
N
VOLTAGE
CURRENT
I N P U T
O U T P U T
Rx / Tx GND
RS 485
M-Bus
2 5 8 11 1 3 4 6 7 9
a
L2
L1
A
2 5 8 11
S1
S1
P1
+ –
33 34 35
X
X
34 35
15 29
N
L3
P1
S1
X X X
P1
LOAD
X
NOTE
The wiring diagrams, show the device complete with pulse output and RS485 or M-Bus interface.
In case of version without of these features, the corresponding terminals must not be considered.
NMERKUNG
uf den Schaltbilder sind immer die Konfigurationen mit Impulsausgang und Kommunikation RS485
oder M-Bus angegeben. Für die Modelle ohne Impulsausgang und Kommunikation RS485 oder M-Bus,
muß man nicht die dazugehörige Verbindungen aufzeichnen.
I N P U T
15 29
2 5 8
11
1
3
4
6
7
9
S1
P1
X
X
I N P U T
2 5 8
11
1
3
4
6
7
9
15 29
S1
S1
P1
P1
I N P U T
VOLTAGE
CURRENT
2 5 8 11 1 3
4 6 7 9
15 29
S1
P1
S1
X
P1
X
S1
P1
I N P U T
VOLTAGE
CURRENT
2 5 8 11 1 3
4 6 7 9
15 29
S1
P1
S1
P1
S1
P1
X X X
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
33 34 35
34 35
X
LOAD
O U T P U T
M-Bus
RS 485
Rx / Tx GND
+ –
33 34 35
34 35
X
X
LOAD
X
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
33 34 35
34 35
LOAD
X
O U T P U T
RS 485
M-Bus
Rx / Tx GND
+ –
33 34 35
34 35
X
X
X
LOAD
10781555W