14. ERROR HANDLING
The control board can store up to 10 diff erent errors, with no. of occurrences limited to 10, for each event.
In case of blocking (severe) error, it is possible to restart the board by pressing both keys "+" and "-" for 5 seconds or by switching off
and on the power supply. When restarting by means of keys, a memory check is performed and automatic recovery of out-of-range
parameters is done. The parameters are set to default factory values, so a new setup should be done, if necessary.
In level 4 menu, parameter "
and the number of occurrences. Use "+" e "-" for scroll the whole list.
At the end of the list, an e it code is presented: quitting (by pressing "F") with
error history is cleared to zero.
Events/warning not severe are stored in memory, without blocking the normal behaviour of the control board.
List of errors and events with the indication of blocking/not blocking:
FAULT AND EVENTS TABLE:
Par
Internal error on memory access.
Out of range memory address.
Fuse F2 or F3 blown or not present.
STOP occurred, changing the normal automation behaviour.(*)
Obstacle detected during operation.
Time-out elapsed while opening.
Time-out elapsed while closing.
Break on U-Link communication.
Programmed maintenance cycles reached.
Close limit switch not working (when present and enabled).
MODBUS: unknown command.
MODBUS: parity parameter error. Internal error.
MODBUS: wrong parameter or data length.
Communication parameter unknown
(*) Events occurrence that change the normal behaviour, such as STOP, obstacle detection, etc., are stored.
For e ample, if STOP input activates during a static status (automation stopped), the event is not saved; but if it prevents a move-
ment or inhibits a command, it is stored.
46 - PERSEO CBE
", shows the list of events and error stored in memory. The display shows alternatively the error code
the error list is preserved, quitting with
Description
the
BLOCKING
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES