Kit Contents
No.
Components
1
4" Stove Adapter
1
3" to 4" increaser*
2
Slip Section 9"L (Adjustable)
3
Wall Pass-thru
4
Tee
5
12" Pipe Length
6
18" Pipe Length
7
36" Pipe Length
8
Wall Support
9
90°Elbow
10
Jet Cap
* Only in the 4" diameter kit
INSTALLATION
The ends of the chimney sections, edges of the cap, roof flashings, tee and other
components can be sharp! We strongly recommend the use of gloves during installation.
Burning solid fuels generates carbon monoxide in low concentration. In higher
concentrations,
exhaust venting system must be
with a high temperature silicone and secured with a minimum of three #8 x ½" self-
DANGER
drilling screws.
The following installation is for reference only and may not represent your type of installation.
Position appliance:
Locate the appliance in accordance with the appliance manufacturer's instructions
and clearance specifications. Pay particular attention to the outlet flue collar of the appliance and
endeavor to position it between the wall studs. Install a stove adapter
temperature sealant onto the appliance flue collar and then secure the stove adapter with a minimum
of three #8 x ½" self-drilling screws. Install the increaser the same way, if necessary.
Rough Frame Wall Opening:
determine the height of the opening it is helpful to preassemble the slip section
adapter or increaser. Mark the location on the wall. Cut and frame the opening. Refer to the table for
rough opening dimensions.
Rough Opening Dimensions
Pipe Diameter
3" (80 mm)
4" (100 mm)
Installation Manual - VORTEX Pellet Vent System
carbon monoxide is toxic and may cause
airtight. All vent connector joints must be sealed
The wall opening should be centered between two wall studs. To
Opening
6 ½" X 6 ½" (165 mm x 165 mm)
7 ½" X 7 ½" (190 mm x 190 mm)
Qty
1
1
1
1
1
1
1
1
1
1
1
death. To prevent this, the
(1)
by first applying high
(2)
and fit to the stove
Page 7