1.
Place unit on a sturdy countertop near a safe GFCI electrical outlet. Ensure all four feet on bottom
of unit are firmly sitting on a level surface.
IMPORTANT: Allow 4 inches of clearance on each side and rear of the unit for proper ventilation
of the refrigeration system. If proper clearance is not maintained the compressor will not be able
to keep the product cold.
CAUTION: To avoid damage to the compressor it must be in an upright position at lease 4 hours
before plugging the unit in.
2.
Clean tank with soap solution. Then flush out the tank with warm tap water.
Whenever emptying the tanks completely the unit needs to be tilted forward at a 45-degree angle to
ensure all liquid is removed.
3.
Pour product into the unit reservoir tanks. It will take about 1.5 liter of product to fill each tank for the
first time. Invert the last bottle vertically and let it sit upside down on the tank inlet.
4.
Plug unit into GFCI outlet for use. Let the unit's refrigeration system cool down the reservoirs for
approximately 2-3 hours. After the appropriate cool down time has lapsed, the compressor will
continue to cycle on and off to keep product cool. The product dispenses between 5
o
(-15 and -9
C) for 115VAC units and it dispenses between 15
units.
To operate depress lever of respective brand beverage and continuous dispense will occur. As the level
in the tank decreases, the internal tank is automatically filled by evacuation of the bottle on top. When a
bottle on top of the unit is completely empty, it must be replaced immediately with a full bottle of the same
product, or performance will degrade. To maintain proper cooling, capacity, and prevent freezing it is
recommended to replace empty bottles immediately with full bottles. Use the visual slots in bottle holders
as a guide to determine volume remaining inside the top bottle.
The unit is supplied with single-handed operation faucets. This allows the bar-staff serving the cold shots
the capability of using one hand to hold the glass while simultaneously activating the lever to allow
beverage to flow. If the valve lever is raised forward and vertical it then allows free-flow of the product
from the respective faucet. This mode is used for filling large glasses, pitchers, cleaning or emptying the
tanks.
Do not tighten down on nut on valve, as this will affect the tank to valve seal.
If the dispenser fails to dispense product see troubleshooting guide.
© 2006-2008, IMI Cornelius Inc.
DRINK RESPONSIBLY

START UP INSTRUCTIONS

OPERATING INSTRUCTIONS

o
F and 25
- 1 -
Cold Shot Owner's Manual
o
o
F and 15
o
o
o
F (-9
C and -4
C) for 230VAC
Publication Number: 621058201OPR