Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
- EN -
7

Installation

Installation of the FiltoMatic CWS
The FiltoMatic CWS is delivered pre-assembled. Assembly is reduced to the outlet and the inlet and dirty
water outlet connections.
The outlet sheath (8) for the dirty water outlet is transparent. In this manner, the degree of soiling of the
outflowing water is visible during future cleaning. Pumping can be stopped as soon as visibly clean
water flows out of the dirt outlet. Cleaning is then completed.
Installation of the outlet (Figure F)
1. Place the flat sealing (5) over the outlet screw (25) pre-fitted on the housing.
2. Screw the outlet (4) on the outlet screw (25).
3. If necessary, connect a DN75 pipe (26) to the outlet (4) as an extension to allow the filtered pond
water to return into the pond. Ensure a minimum incline of 1.5 % for the DN75 pipe.
As an extension for the outlet, OASE recommends the following:
– DN75 pipe, 480 mm, black (OASE Order No. 55043)
– DN75 pipe elbow, 45°, black (OASE Order No. 55044)
– DN75 pipe elbow, 87°, black (OASE Order No. 55045)
– DN75 pipe elbow, T, black (OASE Order No. 55046)
Installation of the inlet (Figure F)
1. Plug the inlet sheath (9) and the flat sealing (6) into the union nut (10) and tighten at the stop valve
thread (21).
2. Slide the hose clip (11) over the hose (24) arriving from the Aquamax. Push the hose on the inlet
sheath (9) and fasten with the hose clip.
Hose recommended by OASE: Spiral hose, green (OASE Order No. 52981)
Prior to the assembly, place the hose end in hot water for two minutes. It will then be easier to slide the
hose onto the inlet sheath (9).
Installation of the dirty water outlet (Figure F)
1. Fit the O ring (7) on the outlet sheath (8) and into the union nut (10). Then tighten to the thread of the
pre-assembled dirty water outlet (22).
2. Plug a DN40 pipe (23) onto the outlet sheath (8). Route the end of the DN40 pipe to a point where the
dirty water to be pumped out can trickle into the ground. Ensure a gravity of 1.5 % to 2 % for the DN40
pipe.
As an extension for the dirty water outlet, OASE recommends the following:
– DN40 pipe, 480 mm, black (OASE Order No. 50307)
– DN40 pipe elbow, 45°, black (OASE Order No. 50308)
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtomatic cws 14000Filtomatic cws 25000

Table des Matières