Function description 
 C 
Drawn  in  by  a  pump  into  the  pump  unit,  the  water 
flows  through  two  filter  chambers  arranged  one  be‐
hind the other. The first filter chamber is filled with ce‐
ramic substrate, the second filter chamber contains a 
20ppi foam filter. 
ACCESSING THE UNIT 
Dismantling the unit head 
How to proceed: 
 D 
1. Slide the closure on each side to the "padlock open" 
symbol. 
2. Lift the unit head from the container.
 
Fitting the unit head 
How to proceed: 
 E 
1. Check that the seal on the unit head is correctly po‐
sitioned. 
– Clean the seal, replace it if damaged. 
2. Ensure that the vent hose is in place and is pointing 
upwards. 
3. Fit the unit head onto the container.
4. Slide  the  closure  on  each  side  to  the  "padlock
closed" symbol.
INSTALLATION AND CONNECTION 
 F, G 
The unit can be installed next to the aquarium or fas‐
tened to the outside of the aquarium with the aid of a 
holder  (not  included  in  the  delivery  scope).  Note 
the  maximum  water  height  above  the  filter. (→ 
Technical data) 
Order of tasks to be carried out: 
1. If the unit is to be installed in a standing position: Fit 
the enclosed rubber feet onto the base of the con‐
tainer. 
2. Position the filter media (→ Cleaning/replacing the 
filter media) 
3. Establish  the  connections  (→ Establishing  the  con‐
nections) 
Establishing the connections 
Assembling the suction unit 
How to proceed: 
 H 
10 
 Assemble the suction unit.
 
 
Assembling the flow‐out unit 
How to proceed: 
 I 
 Assemble the flow‐out unit. 
– The water distributor can be used instead of the
flow‐out pipe. 
Connecting the hose 
The procedure is identical for the inlet (IN) and outlet 
(OUT). 
 
How to proceed: 
 J 
1. Shorten the hose to the required length. 
 
– Chose the length so that the hose cannot kink in
the intended installation position. 
2. Screw the union nut onto the hose connector of the
connection unit. 
3. Push the hose onto the hose connector and turn the 
union nut counter‐clockwise to fix the hose in place.
4. Push the other end of the hose onto the hose con‐
nector at the suction unit/flow‐out unit and turn the
union nut counter‐clockwise to fix the hose in place.
 C 
 Fasten  the  suction  unit  and  flow‐out  unit  in  the 
aquarium using suction cups.
COMMISSIONING/START‐UP 
N O T E  
Thoroughly rinse out all filter material with warm tap 
water before using for the first time in order to remove 
any soiling. (→ Cleaning/replacing the filter media) 
 
N O T E  
Ensure that the pump never runs dry! 
The pump will be destroyed. 
 Regularly  check  the  water  level  and  circulation  in 
the filter and in the aquarium. 
How to proceed: 
 N 
 Completely fill the container with water and place it 
next to the aquarium. 
 Route  the  power  connection  cable  such  that  it 
forms a drip loop! 
Switching on: Connect the unit to the mains. The unit 
switches  on  immediately.  When  the  unit  is  switched 
on, it takes several minutes for the air to escape from 
the unit (this makes a noise). 
Switching off: Disconnect the unit from the mains. 
 
FiltoSmart 60 