Functions Of The Control Panel - Husqvarna DE 110S Manuel D'utilisation

Extracteur de poussière monophasé
Masquer les pouces Voir aussi pour DE 110S:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To lock and unlock the transport
wheels
For operation on a surface with a slope it is necessary to
lock the transport wheels.
WARNING:
bearings must be clean and without dust
for safe operations. Refer to
schedule on page 19 .
1. Hold the product in a stationary and safe position.
2. Push down the wheel brake on each side to lock the
wheels. (Fig. 13)
Note:
DE 110S/DE 110 has only 1 wheel brake.
3. Pull up the wheel brakes to unlock the wheels.

Functions of the control panel

The control panel controls and monitors important
functions and setups of the product. Refer to
on the control panel (DE 110/DE120) on page 23 to
find solutions for the warnings.
(Fig. 14)
1. The prefilter is clogged. Refer to
particles from the prefilter during operation on page
17 .
2. The HEPA filter is clogged, damaged or missing.
Warnings on the control panel (DE 110/
Refer to
DE120) on page 23 .
Warnings on the control panel (DE
3. Warning. Refer to
110/DE120) on page 23 .
®
4. Bluetooth
connection. Refer to
connectivity with fleet on page 15 .
5. Diameter change function for hose, refer to
the hose nozzle diameter on page 16
6. Automatic start, refer to
(Only 230V DE 110S and DE 110) on page 16
7. e-Flow button, refer to
8. On/Off button
e-Flow function
The product has an e-Flow function. This function
automatically adjusts the airflow to the workload for
optimal performance. The product always starts with the
last settings used.
Functions of the control panel on page 16 to
Refer to
engage or disengage the function.
Automatic start function (Only 230V DE 110S
and DE 110)
The product can be used to collect dust from equipment
such as a grinder or power cutter. When you start
the equipment that is connected to the electrical outlet
on the product, the product starts automatically. When
16
Wheels and
Maintenance
Warnings
To remove dust
To use embedded
To select
Automatic start function
e-Flow function on page 16
you stop the equipment, the product operates for
approximately 10 seconds to empty the hose and then
stops.
Airflow warning system
The airflow in the suction hose must be more than 20
m/s (66 ft/s).
For the minimum airflow with the selected hose diameter
refer to the table.
DE 110
in.(mm)
CFM (m
1 (27)
24 (41)
1 ¼ (32)
34 (58)
1 ½ (38)
48 (82)
1 ⅔ (42)
59 (100)
2 (51)
87 (147)
Note:
If the airflow is less than 20 m/s (66 ft/s), the
sound alarm and the warning symbol comes on. Refer to
Warnings on the control panel (DE 110/DE120) on page
23 .
To select the hose nozzle diameter
Note:
If you do not select the correct hose diameter,
the airflow warning system will come on.
When you start the product, the last selected hose
diameter is automatically selected.
Push the button to select the correct hose diameter.
The green LED tells which diameter you have
selected. (Fig. 15)
To start and stop DE 110S
Note:
Wait for 5 seconds after you start the product
to operate with full suction. The suction is not at full
capacity directly at start.
1. Make sure that the frequency and voltage shown on
the rating plate agree with the power supply.
2. Make sure that the On/Off switch is set to the "0"
position.
3. Connect the product to an applicable power socket.
4. Push the On/Off switch. (Fig. 16)
a) Push "I" to start the product.
DE 120
3
/h)
in.(mm)
CFM (m
1 ½ (38)
48 (82)
1 ⅔ (42)
59 (100)
2 (51)
87 (147)
2 1/2 (63)
132 (224)
3 (76)
192 (327)
1587 - 007 - 24.01.2022
3
/h)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

De 110De 120

Table des Matières