Standalone operating mode
Temperature of the device head
Lamp status
Note regarding the main display in operating modes with external control: As soon as
the control signal is interrupted, the characters in the centre of the display begin to flash. The
flashing stops when a control signal is present.
Warning: If the warning symbol (triangle with exclamation mark) appears in the display, there is
a fault with one or more components in the device. The affected components can be seen in the
Info Menu under Error Info. If the error cannot be rectified by a restart or reset, please contact
an authorised service centre.
W-DMX™
To pair a W-DMX receiver with a W-DMX compatible transmitter, the Reset command must be
executed in the menu item WDMX under Receiver (select and confirm Reset). The receiver is
now in pairing standby and waiting for a pairing request from a transmitter. Start the pairing
by selecting Link in the menu of the transmitter and confirming; the pairing now takes place
automatically. In the same way, several receivers can be paired simultaneously or one after
the other to a transmitter (e.g. for master / slave operation). A W-DMX connection is always
maintained until the connection is disconnected by means of the Reset command in the receiver
or the Unlink command in the transmitter, regardless of whether a device has been disconnected
from the power supply in the meantime.