INSTALLATION MANUAL
N
GALEOW
Illuminated keypad - Wiegand
STAND ALONE MODE
TELACCESS
- Dipswitch address set up
- Dip4 = ON
DIP SWITCH adressing
1
ON
OFF
ON
OFF
ON
ST1 (Programming jumper) : Normal
ers
EXE-CDVI_IM GALEOW CMYK A5 EN-FR 07.indd 15
INTBUSW (Door controller)
Terminal block : Motherboard
Terminal block : Motherboard
+ ~ - Input voltage DC or AC, 12V or 24V
Without jumper : without clock
With jumper : with clock
Terminal block - 3 points : Piggyback board
2
3
4
Mode
ON
ON
ON
Front plate
ON
ON
ON
Reader 1
OFF
ON
ON
Reader 2
OFF
ON
ON
Reader 3
ON
OFF
ON
Reader 4
V
Input voltage -
12
Input voltage +
1
Data O
2
Clock
3
Data 1
R
N/C contact eletromagnetic lock (+)
C
Common contact power supply (+)
T
N/O contact electric release
R
N/C contact alarm
C
Common
T
N/O contact alarm
P1
Request-to-enter input
M
Common ( P1 et P2 )
P2
Request-to-enter input
E
Door contact, N/C (Door closed) and N/O (Door open)
L
Reader activation imput (N/O) reader enabled and (N/C) reader disabled
M
Common ( E and M ) or (E and L)
A
RS485 Bus (All the A must be connected together in daisy chain)
B
RS485 Bus (All the B must be connected together in daisy chain)
7
LED > Red color
8
LED > Green color
9
Buzzer
CENTRALIZED MODE
- TERENA
- Address programming during installation
- Dip4 = OFF
ST1 (Programming jumper)
Normal (As standard)
Installation