Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Action Current mA
Fuse
Power Cord
Signal cable
※ Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10 m. If power cord is
>10 m, wire diameter must be increased. The signal cable can
be extended to 50 m at most.
2.
Installation and Requirements
The swimming pool heater must be installed by a pool professional. End
users are not qualified to install the heater. Damage may occur to the
heater or threaten the safety of the user.
A. Installation
1) The swimming pool heater should be installed in a location with good
ventilation;
2) The frame must be fixed by bolts (M10) to concrete foundation or
brackets. The concrete foundation must be solid and fastened; the
bracket must be strong and antirust treated;
3) Don't stack substances that will block air flow near inlet or outlet area,
and no barrier within 20in behind the main heater, or the efficiency of the
heater will be reduced or even haulted;
4) The heater needs an appended pump (Supplied by the user). The
recommended pump specification-flux: refer to Technical Parameter,
Max. lift ≥10m;
Rated Residual
A
(mm²)
(mm²)
HP40BEE
HP50BEE
12
30
12
3×2.5
3×2.5
3×0.5
3×0.5
HP65BEE1
15
18
30
30
15
18
3×4
3×0.5
8