Heating Specifications 
 
• Maximum Burn Time** .............................................................................            Up to 14  hours 
• Approximate Square Footage Heated*** ...............................................            2,400 sq. ft. 
• Firebox Capacity........................................................................................         23 lbs. 
• Flue Collar .................................................................................................                                                      6 .0 in. round 
 
Dimensions (Inches) 
 
 
 
EPA and Safety Compliance Specifications 
EPA Compliance .....................................................................................     Certified 
• 
Particulate Emissions ............................................................................       3.472  grams/hr 
 CO Emissions  .............................................................................................         146.09 grams/hr 
• 
Efficiency* ...........................................................................................         70.32% HHV 
• 
Tested To   ..................................................................                    UL‐1482‐2011, ULC‐S627‐00, 
ASTM E2515‐11, ASTM E2780‐10, EPA Test Method 28R‐15, CSA B415.1‐10 
 
** ‐ Maximum burn times are heavily dependent on the type of wood burned in the stove; as such, these numbers 
may vary. 
*** ‐ The maximum  heating capacity of this unit can vary greatly based on climate, construction style, insulation 
and a myriad of other factors.  Use this information in conjunction with a BTU loss calculation for your home to 
determine if this unit will be sufficient for your needs. 
 
"U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate 
emission standards for wood heaters. Not approved after sale after May 15, 2020. 
 
TAMPER WARNING: "This wood heater has a manufacturer‐set minimum low burn rate that 
must not be altered. It is against federal regulations to alter this setting or otherwise 
operate this wood heater in a manner inconsistent with operating instructions in this 
manual." 
"This wood heater needs periodic inspection and repair for proper operation. It is against 
federal regulations to operate this wood heater in a manner inconsistent with operating 
instructions in this manual."