Other Components continued:
At this point you can access
the primary air control
damper assembly,
thermostatic actuator
assembly and the damper
release lever. Although these
shouldn't need to be replaced,
they can be easily. The
primary air control damper
assembly can be replaced by
removing the small spring
handle from the front of the
unit, then sliding the assembly out. Replace by sliding the new assembly through the same hole
and the rod through the front of the stove. Replace the spring handle. The thermostatic
actuator assembly can be replaced by using a 5/16" socket to remove the two screws that hold
the assembly. Install the new assembly using the same two screws. The damper release lever
can be replaced by removing the ½" bolt. When reinstalling the damper be sure it is installed
the same as when removed.
Blower: The wood stove was also designed for use with a convection blower for additional heat
circulation. The stove is constructed with side convection channels which allow the room air
blower to pick up heat from the hottest regions of the stove and transfer it into the home. The
mounting screws for the blower are installed into the rear convection channel at the factory;
mounting the blower only requires a 5/16" open end or socket wrench to remove these screws
and install the blower.
When routing the power cord, take care to keep away from hot areas of the unit and remember
that this blower is for use only with the stove. Please see the diagram below for clarification on
the room air blower installation.
This unit can use the AC‐16 (which comes standard with the unit) or the AC‐30 upgrade blower.
Both are installed using the four factory installed 5/16" screws.
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed
no less than every three months of normal operation. To properly lubricate the blower, use an eye dropper or
similar dispensing device to drip 5‐7 droplets of SAE 20 oil into the oil port on the side of the blower motor
OPTIONAL ACCESSORIES
(4) 5/16" head, self‐tapping
screws (pre‐installed in unit).
Warning: Disconnect power
from fan before installation.
Page | 25