1 – Display
2 – "Soft" buttons – used to select menu options.
3 – Arrow buttons – used to move the cursor around
the screen or adjust values.
4 – On/off button
5 – Headset connection (at the side)
6 – Battery (at the side)
7 – Compartment containing USB connection and mem-
ory card (at the side)
7.3.1 Switching on and off
To switch the monitor on, press and hold the On/off but-
ton for 1 second. The monitor will display a boot-up
screen for about 15 seconds until it is ready for use. To
switch off, press and hold the On/off button for about
1 second. The system switches itself off.
7.3.2 General screen layout
Main display area
Status
bar
Status bar
Battery level. All 5 blocks filled indicates that the battery
is fully charged. Warnings will appear when the level
reaches the last block and about 15 minutes and 5 min-
utes before the battery is totally exhausted. Thereafter,
the system will beep every two minutes until it is switched
off. If the monitor is switched off when battery power is
low, it will not be possible to switch it back on until the
battery has been recharged.
54
Printed: 07.07.2013 | Doc-Nr: PUB / 5070389 / 000 / 00
All manuals and user guides at all-guides.com
Information bar
– Memory card
Indicates the memory source being used and the free
space available. A full bar indicates that memory is full.
When the memory card is inserted, it is used as the
memory source and the symbol appears as above. If the
card is removed, the monitor uses its own limited-capac-
ity internal memory which provides space for a mini-
mum of 20 scans. The symbol then changes to the fol-
lowing:
– Internal memory
– Connected to PC for data transfer
– Connected to PC for data transfer, memory card
removed: no data transfer possible.
– Infrared symbol – indicates the status of the
infrared port.
– Ready
– Data backup
– Transmitting/receiving data
– Voice record available
– Bar diameter fixed
– Scan calibrated (Imagescan only)
Information bar
Information about the items currently shown in the main
display area appears here. This varies with the type of
scan being viewed.
Menu area
The menu items differ according to the operation being
carried out, with the menu title being displayed at the
Menu
top. Each item or command is executed by pressing the
area
associated soft button.
Main display area
Scanned images, settings and project information are
displayed here.
7.3.3 Setup
General settings for the monitor are made here. Use the
soft buttons to access a menu item and the arrow but-
tons to move between options in an item and to select
values.