KPS-MT50 • Digital multimeter
- Temperature Coefficient:
0.1 ºC (specified accuracy) / ºC (<18 ºC or >28 ºC)
- MAX. Voltage between terminals and earth ground:
750V AC rms or 1000V DC.
- Fuse Protection: mA: fuse (FF400mA/1000V), A:fuse (FF10A/500V)
- Sample Rate: 3 times/sec for digital data and 30 times/sec for the analog bar
- Display: 4000 counts with analog bar LCD display. Automatic indication of
functions and symbols.
- Over Range indication: LCD will display "OL".
- Low battery indication: The "
is under the proper operation range.
- Polarity indication: "-" displayed automatically.
- Power source: 9V
- Battery type: NEDA 1604, 6F22, or 006P.
- Dimensions: 195(L)x92(W)x55(H) mm.
- Weight: 380g. Approx. (battery included).
4.2 Measurement specifications
Accuracy is specified for one year after calibration, at operating temperatures
of 18ºC to 28ºC, with relative humidity at 0% to 75%.
Accuracy specifications take the form of: ±(% of Reading + Number of Least
Significant Digits).
4.2.1 DC Voltage
Range
400mV
4V
40V
400V
1000V
Input impedance: 10MΩ
Max. input voltage: 1000Vdc or 750V ac rms.
" is displayed when the battery
Resolution
0,1mV
1mV
10mV
100mV
1V
37
Accuracy
±(0,5% of reading + 2 digits)
±(0,8% of reading + 2 digits)