4.2.4 Resistance
Range
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Overload protection: 250V dc or 250Vac rms.
Open Circuit Voltage: Less than 700mV..
4.2.4 Diode
Range
Forward DC Current: approx. 1mA
Reversed DC Voltage: approx. 2.8V
Overload protection: 250Vdc or 250Vac rms.
4.2.6 Audible continuity
Range
Resolution
0,1Ω
1Ω
10Ω
100Ω
1kΩ
10Ω
Resolution
Display read approx. forward voltage of
1mV
39
Accuracy
± (0,8% of reading +3 digits)
± (0,8% of reading +1 digit)
± (1,0% of reading +2 digits)
Accuracy
diode
Continuity beeper
≤60Ω