Installation; Regulations; Flue Duct; Installing The Fire - Dik Geurts YUNA Instructions D'installation

Masquer les pouces Voir aussi pour YUNA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.
INSTALLTION
5.1

REGULATIONS

Pleas install the fire in accordance with the applicable national, local and constructional
(installation) regulations.
Observe the regulations/instructions in this manual.
5.2

FLUE DUCT

The following requirements apply to the flue duct:
− the flue duct must be inspected in advance by a specialist;
− the flue duct must be suitable for connection to a wood stove;
− the fire must be connected to a single, unshared fire duct;
− the flue duct must be clean and gastight;
− the bend in the flue duct may amount to a maximum of 1.5 meters;
− the diameter of the flue duct must be equal to the diameter of the stove's flue exhaust;
− the draught in the flue duct must be at least 12 Pascal;
− in case of a duct with a draught that is too strong, it may be necessary to install a flue valve;
− flue pipes must be placed in such a way that they drain towards the stove;
− the flue duct must be self supporting and may not rest on the stove;
5.3

INSTALLING THE FIRE

Install the fire as follows:
Caution
- Do not make any changes to the fire;
- suspend the fire from a wall with sufficient load-bearing strength;
- suspend the fire from a wall made of non-combustible material;
- always place the fire and/or the flue pipes at a minimum distance of 700
mm from combustible objects and/or materials;
- place a fire-resistant floor plate under the fire, extending 300 mm in front of
the stove, if it is suspended above a floor made of combustible material;
- do not cover the fire and/or do not wrap it in an insulation blanket or any
other material;
- observe the requirements for the flue duct, as stated in paragraph 5.2.