ARTHUR MARTIN ASL5346LA Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem and alarm code
The appliance does not fill
with water.
The display shows
The appliance does not drain
the water.
The display shows
The anti-flood device is on.
The display shows
The appliance stops and
starts more times during op-
eration.
The program lasts too long.
The remaining time in the dis-
play increases and skips
nearly to the end of program
time.
Small leak from the appliance
door.
The appliance door is difficult
to close.
Rattling/knocking sounds
from inside the appliance.
The appliance trips the cir-
cuit-beaker.
Refer to "Before first use",
"Daily use", or "Hints and
tips" for other possible causes.
Possible cause and solution
• Make sure that the water tap is open.
• Make sure that the pressure of the water supply is not too
low. For this information, contact your local water authority.
.
• Make sure that the water tap is not clogged.
• Make sure that the filter in the inlet hose is not clogged.
• Make sure that the inlet hose has no kinks or bends.
• Make sure that the sink spigot is not clogged.
• Make sure that the filter in the outlet hose is not clogged.
• Make sure that the interior filter system is not clogged.
.
• Make sure that the drain hose has no kinks or bends.
• Close the water tap and contact an Authorised Service Cen-
tre.
.
• It is normal. It provides optimal cleaning results and energy
savings.
• Select the TimeManager option to shorten the program
time.
• If the delayed start option is set, cancel the delay setting or
wait for the end of the countdown.
• This is not a defect. The appliance is working correctly.
• The appliance is not levelled. Loosen or tighten the adjusta-
ble feet (if applicable).
• The appliance door is not centred on the tub. Adjust the rear
foot (if applicable).
• The appliance is not levelled. Loosen or tighten the adjusta-
ble feet (if applicable).
• Parts of the tableware are protruding from the baskets.
• The tableware is not properly arranged in the baskets. Refer
to basket loading leaflet.
• Make sure that the spray arms can rotate freely.
• The amperage is insufficient to supply simultaneously all the
appliances in use. Check the socket amperage and the ca-
pacity of the meter or turn off one of the appliances in use.
• Internal electrical fault of the appliance. Contact an Author-
ised Service Centre.
Once you have checked the appliance,
deactivate and activate the appliance. If the
problem occurs again, contact an
Authorised Service Centre.
17