8.2.7.4
Activating/deactivating a switching point
See 8.2 for the steps to call up the menu.
The timer can be selected by pressing the
[F] [G]. Confirm the timer selection by pressing the
ENTER button [D]. A switching point can now be
activated/deactivated by pressing the
[G] followed by the Enter button [D]. The
programmed switching points can now be selected by
pressing the
activated/deactivated by pressing the ENTER button
[D].
8.2.8
Setting the Efficiency
*Applies only to MICROBEFREE, SMOKEFREE SPECIAL and
DUSTFREE SPECIAL*
Setting the efficiency changes the (high) voltage at the
ElectroMax, thus influencing the efficiency. If the efficiency has to
be changed, this should be carried out by a qualified fitter.
See 8.2 for the steps to call up the menu. The efficiency can be
selected by pressing the
button [D] allows the efficiency to be set from Low to Extreme
with the
buttons [F] [G]. To confirm the selection, press the
pq
PROGRAM button [H].
- Low
- Medium
- High
- Extreme
8.2.9
Setting the High Voltage Hysteresis
*Applies only to MICROBEFREE, SMOKEFREE SPECIAL and
DUSTFREE SPECIAL*
Setting of this hysteresis ensures that the high voltage is switched
on only after the air cleaner has been switched on.
See 8.2 for the steps to call up the menu. The hysteresis can be
selected by pressing the
button [D] allows the hysteresis to be set from 30 minutes to
max. 4 hours with the
pq
selection, press the PROGRAM button [H].
- 30 minutes
- 60 minutes
- 120 minutes
- 240 minutes
This time is set as standard to "0" so that the high voltage is
switched on as soon as the air cleaner is switched on.
8.2.10
Blocking push-button
This function blocks the push-button of the operating panel on
the VisionAir Blue Line. The air cleaner can then only be operated
using the remote control.
See 8.2 for the steps to call up the menu. Blocking can be selected
buttons [F] [G].
by pressing the
pq
20
buttons
pq
buttons [F]
pq
buttons [F] [G]. The switching point is
pq
buttons [F] [G]. Pressing the ENTER
pq
buttons [F] [G]. Pressing the ENTER
pq
buttons [F] [G]. To confirm the
8.2.11
Setting the Maximum Speed with the Remote Control
This function is used to limit the maximum fan speed that can be
set with the remote control.
See 8.2 for the steps to call up the menu. The maximum speed
setting can be selected by pressing the
Pressing the ENTER button [D] allows the maximum speed to be
set from 1 to 8 with the
selection, press the PROGRAM button [H].
- Speed 1
- Speed 2
- Speed 3
- Speed 4
- Speed 5
- Speed 6
- Speed 7
- Speed 8
8.2.12
Setting the Minimum Running Time
Setting of the minimum running time ensures that the air cleaner
remains active for the set running time after an action started by
the gas sensor, dust sensor or PIR.
See 8.2 for the steps to call up the menu. The minimum running
time can be selected by pressing the
Pressing the ENTER button [D] allows the minimum running time
to be set from 15 minutes to one hour with the
[G]. To confirm the selection, press the PROGRAM button [H].
- 15 minutes
- 30 minutes
- 60 minutes
8.2.13
Reset
A reset sets all the settings back to the standard settings. The time
is nevertheless retained.
See 8.2 for the steps to call up the menu. The reset can be
selected by pressing the
The reset is performed by pressing the ENTER button [D]. A
counter counts down (5, 4, 3, 2, 1) on the display.
buttons [F] [G].
pq
buttons [F] [G]. To confirm the
pq
buttons [F] [G].
pq
buttons [F]
pq
buttons [F] [G].
pq