KLQ - CO
TECHNICAL DATA
Pressure dependence:
Long-term stability:
Gas exchange:
Ambient temperature:
Response time:
Electrical connection:
Enclosure:
Enclosure dimensions:
Cable gland:
Protective tube:
Process connection:
Protection class:
Protection type:
Standards:
Optional:
®
AERASGARD
KTM - CO
AERASGARD
®
KLQ - CO
®
AERASGARD
KFTM - CO
AERASGARD
®
KFTM - LQ - CO
Type ⁄ WG02
KTM - CO
- SD
2
K TM-CO2-SD-U
KLQ - CO
-W
2
K LQ-CO2-W
K LQ-CO2-W-DISPL AY
KFTM - CO
-W
2
K F TM-CO2-W
K F TM-CO2-W-DISPL AY
KFTM - LQ - CO
-W
2
K F TM-LQ-CO2-W
K F TM-LQ-CO2-W DISPLAY
Outputs:
Equipment:
Note:
Accessories
SF-M
Metal sinter filter, Ø 16 mm, L = 32 mm, exchangeable
stainless steel V4A (1.4404)
- W ⁄ KFTM - CO
2
± 0.13 % ⁄ mm Hg
< 2 % in 15 years
by diffusion
–10...+60 °C
< 2 minutes
2
0.14 - 1.5 mm
, via screw terminals
plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced, 
with quick-locking screws (slotted ⁄ Phillips head combination),
colour traffic white (similar to RAL 9016),,enclosure cover for display is transparent!
126 x 90 x 50 mm (Tyr 2)
M 16 x 1.5; including strain relief, exchangeable
TM
PLEUROFORM
, material polyamide (PA6), with torsion protection, Ø 20 mm, v
without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm)
via flange made of plastic (included in scope of delivery)
III (according to EN 60 730)
IP 65 (according to EN 60 529) enclosure only! (PLEUROFORM IP 30)
CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014 ⁄ 30 ⁄ EU
three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO
- SD
Duct sensor for temperature and CO
2
- W
Duct sensor for air quality (VOC) and CO
2
- W
Multifunctional duct sensor
2
for humidity, temperature and CO
- W
Multifunctional duct sensor
2
for humidity, temperature, air quality (VOC) and CO
Measuring Range
Humidity
Temperature
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0 -10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs) –
Standard duct sensor KTM - CO
W = changeover contact – Standard duct sensor KTM - CO
This unit must not be used as safety-relevant device!
- W ⁄ KFTM - LQ - CO
2
2
2
content, Deluxe
2
CO
VOC
2
(switchable)
0...2000 ⁄ 5000 ppm
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
(switchable)
0...2000 ⁄ 5000 ppm
0...2000 ⁄ 5000 ppm
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
- SD with fixed output 0 -10 V!
2
11
- W ⁄ KTM - CO
- SD
2
= 30 m/s (air)
max
content
2
content, Standard
content, Premium
2
content, Deluxe
2
Equipment
Item No.
Display
1501- 8112-1001- 200
W
1501- 8111- 7301-20 0
W
1501-8111- 7371- 200
W
1501- 8116- 7301- 200
W
1501- 8116- 7371- 200
W
1501- 8118- 7301- 200
W
1501- 8118- 7371- 200
- SD without changeover contact !
2
7000- 0050-2200- 100
Rev. 2018 - V29 GB