COMBINED FAN INSTALLATION INSTRUCTIONS
COMBINED INSTRUCTIONS
1. Do not operate the fan or plug it in without the fan being permanently installed on the stove (fire).
2. When the fan is in place, the electrical cord should be routed as close to the floor as possible and outside
the hearth, away from the unit and wall clearances. Route the electrical cord away from the unit to prevent
damage to the cord insulation. Plug into a standard three prong 110-volt outlet or a 240-volt outlet for use
in Australia.
3. Make sure that the fire in the stove is out, and it has cooled down to room temperature before any
maintenance.
4. Follow normal instructions to continue burning.
OSBURN 1000
1.
Install the two formed mounting plates onto the fan housing as shown in figure 1 and fasten with the four
provided screws (a) through the holes as indicated.
2.
Remove the two bottom heat shield screws (b) and locate the fan and mounting plate assembly between
the inside of the heat shield and the two heat shield spacers as shown in figure 2.
3.
Replace the heat shield screws through the heat shield holes, the mounting bracket slots and into the
spacers to secure the assembly.
OSBURN 1100
1.
Install the two formed mounting plates onto the fan housing as shown in figure 3 and fasten with the four
provided screws through the holes as indicated.
2.
Align the holes of the mounting plate with the holes on the outside of the heat shield and fasten with the
two provided screws as shown in figure 4.
3.
For insert applications, turn the fan switch to the high speed position before installation.
OSBURN 1600
1.
Install the two formed mounting plates onto the fan housing as shown in figure 1 and fasten with the four
provided screws (a) through the holes as indicated.
2.
Align the holes of the mounting plate with the holes on the outside of the heat shield and fasten with the
two provided screws as shown in figure 5 and 6.
FABRIQUÉ AVEC FIERTÉ AU CANADA / PROUDLY MADE IN CANADA
FOR OSBURN MODELS
1000, 1100 & 1600 WOODSTOVES
45105

Publicité

loading

Sommaire des Matières pour Osburn 1000

  • Page 1 COMBINED FAN INSTALLATION INSTRUCTIONS FOR OSBURN MODELS 1000, 1100 & 1600 WOODSTOVES COMBINED INSTRUCTIONS 1. Do not operate the fan or plug it in without the fan being permanently installed on the stove (fire). 2. When the fan is in place, the electrical cord should be routed as close to the floor as possible and outside the hearth, away from the unit and wall clearances.
  • Page 2: Maintenance & Care

    OPERATION FAN CONTROL NORTH AMERICA The fan control is variable speed (rheostat). AUSTRALIE The fan control is an « ON / OFF » switch. MAINTENANCE & CARE Clean the fan air inlet screen regularly. The fan should be kept clean and dust free. Life of the fan will be shortened if operated in a dust filled environment or if restricting air supply overheats the fan.
  • Page 3 Figure 1 Figure 2 45105 FABRIQUÉ AVEC FIERTÉ AU CANADA / PROUDLY MADE IN CANADA...
  • Page 4 Figure 3 Figure 4 45105 FABRIQUÉ AVEC FIERTÉ AU CANADA / PROUDLY MADE IN CANADA...
  • Page 5 Figure 5 Figure 6 45105 FABRIQUÉ AVEC FIERTÉ AU CANADA / PROUDLY MADE IN CANADA...
  • Page 6 45105 FABRIQUÉ AVEC FIERTÉ AU CANADA / PROUDLY MADE IN CANADA...
  • Page 7 INSTRUCTIONS POUR INSTALLATION DU VENTILATEUR POUR POÊLES OSBURN MODELES 1000, 1100 ET 1600 INSTRUCTIONS COMMUNES Ne faites pas fonctionner le ventilateur ou le brancher sans que celui-ci soit installé de façon permanente sur votre poêle ou votre encastrable. Une fois le ventilateur installé, le cordon électrique devrait être gardé le plus prêt possible du sol et de l’extérieur de l’âtre, loin de l’unité...
  • Page 8: Fonctionnement

    FONCTIONNEMENT Attendez que le poêle atteigne la température idéale de fonctionnement (environ 1 heure) avant de faire fonctionner le ventilateur, puisque l’augmentation de circulation de l’air en provenance du ventilateur dissipera la chaleur et affectera l’efficacité de la combustion au démarrage. LE CONTRÔLE DU VENTILATEUR AMERIQUE DU NORD Le contrôle du ventilateur est à...

Ce manuel est également adapté pour:

11001600