If the starter does not turn the engine over, shut off
the starter immediately. Do not make further attempts to
start the engine until the condition is corrected. Do not
jump start using another battery.
5. Once engine has started, slowly move choke lever to no
choke.
6. Allow the unit to run for two (2) minute warm-up.
7. Turn main breaker to ON position.
8. Test the GFCI receptacle(s) on the unit. Push the test button.
The reset button should pop out and there should be no
power at the receptacle. Apply a test load or lamp to each
receptacle to verify. IF THE RESET BUTTON DOES NOT
POP OUT, DO NOT USE THE RECEPTACLES(S). SEE
DEALER FOR SERVICE IMMEDIATELY.
9.
If GFCI receptacle(s) test correctly, firmly push the reset
button to restore power. A distinctive click should be heard or
felt when this is complete. IF THE RECEPTACLE(S)
DO NOT RESET PROPERLY, DO NOT USE THE
RECEPTACLE(S). SEE DEALER FOR SERVICE
IMMEDIATELY.
10. Turn idle control switch to ON position. Loads can now be
applied to unit.
NOTE: This engine is equipped with a "Low Oil" shutdown
system for engine protection. The engine stops when
the oil level gets too low. The engine will not restart
without adding oil. Refer to Preparing the Generator;
Engine Fuel Capacity for instructions on adding oil.
SHUTDOWN
1. Remove all load by turning off electrical appliances and
unplugging electric cords.
2. Allow engine to run no load condition to cool for two (2) minutes.
NOTE: Failure to allow the engine to cool for two (2) minutes may result
in damage to the generator.
3. Close fuel valve on unit or engine.