F01 no ignition
F02 it is not stabilized
F03 the temperature of the exhaust gas is too low
F04 room temperature error
F05 too high temperature of the printed circuit board
too large pressure difference between the exhaust
F06
gas and the air of the room
F07 StB, too high internal temperature
F08 exhaust gas fan
worm engine has been operating for more than 40
F10
seconds
the contact element of the pressure switch closes
F11
upon the first inspection
F13 the temperature of the exhaust gas is too high

6.2. ACKNOWLEDGMENT OF THE ALARM

Press the P2 key (ON/OFF) for short to acknowledge the alarm, or press the P2 keys (ON/OFF)
longer to switch the boiler off.
If the equipment cannot be stopped, request help as the case may be.
It is forbidden to unplug the boiler from the socket in the course of operation! The boiler
shall be switched off in advance, and the operator shall wait until the fan fully stops (the
fuel burns down).

7. ELECTRIC POWER SUPPLY

The equipment may be operated solely from an electric power supply socket provided
with protective grounding.
230 V AC / 50 Hz (allowable voltage fluctuation: 195–255 V).
Use only the power supply cord provided as an accessory!
Ensure that the cord should not come in contact with the hot surfaces of the boiler
(exhaust gas pipe, etc.).
The connecting cable has to be replaced immediately in case it is damaged, or show
damaged parts. Contact our Customer Services to procure a spare cord.
the pellet tank is empty, the quality of the fuel is not
appropriate
too little heat is generated after ignition
the pellet tank is empty, the quality of the fuel is not
appropriate
let the boiler cool down
contaminated chimney / exhaust gas pipe / boiler
let the boiler cool down
contaminated chimney / exhaust gas pipe / boiler,
failed fan
excessive draft in the chimney, failed pneumatic
storage space