WP2-8_GB
70 / 189
Dismounting the cover of the
combustion chamber
After removing the two butterfly nuts, the
cover of the combustion chamber can be
lifted out from the boiler body by pulling it
upwards at an angle.
Warning!
When resetting these elements, pay
proper attention to the appropriate
tightness of the screws and the
undamaged nature of the gaskets!
The lack of adequate tightness may
cause malfunctioning!
Removal of the guide plate
After cleaning the guide plate, the plate
can be removed from the boiler body by
tilting it upwards at an angle.
Warning!
When
resetting
these
elements,
ensure
their
correct
positions,
because incorrect resetting may lead