Maintenance; Increase Preliminary Filling Pressure - wepump WEPRESS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance

Mortal danger due to electric shock!
Disconnect the mains plug before carrying out any work on the device.
GB
Danger!
Risk of injury!
Make sure that the device and connected accessories are depressurized before car-
Danger!
rying out any work on the device.
Risk of damage to the device!
All gaskets must be renewed after each disassembly of components.
Attention!

Increase preliminary filling pressure

If – over the course of time – the pump starts up after just a slight removal of water (approx. 0.5 l),
the preliminary filling pressure in the boiler must be re-established.
1. Disconnect the mains plug.
2. Open pressure line (turn on water spigot or nozzle), allow water to completely run off.
3. Unscrew plastic butterfly valve (9) on the front side of the boiler; the air-control valve is
located behind it.
4. Attach air pump or compressor hose to the air-control valve with a "tire valve" connection and
pressure gauge.
5. Pump up [inflate] to the designated preliminary filling pressure (preliminary filling pressure:
1.8~2.0 bar).
6. Reconnect the device and check function.
Danger of damage to the device!
If the conveyed water is highly contaminated, clean the filter after each use. A
Attention!
stopped-up filter will damage the pump!
– Unscrew filter housing (A) and take out filter cartridge.
– If needed, soak filter cartridge in warm water for a short while.
– Rinse filter cartridge with clear water; brush out stubborn dirt
from inside using a soft brush.