The device can also be connected firmly to a pipe system (e. g. for domestic water supply in the
interior). In this case, the device should be connected to the pipe system with elastic high-pres-
sure flexible hose lines in order to prevent vibrations.
Risk of injury!
GB
If the components are not compression-proof or if they are improperly installed, the
Danger!
pressure line could burst during operation. Risk of injury from liquid spurting out!
Note:
The device may only be used for industrial water supply, e. g. from the toilets, wash-
ing machine, etc.
It may not be used for drinking water supply.

Electrical connection

Mortal danger due to electric shock!
Do not operate the device in wet surroundings!
Danger!
The device may only be operated under the following conditions:
• The device may only be connected to outlets with protective contacts that have been profes-
sionally installed, grounded and inspected.
• Mains voltage and fuse protection must comply with the technical data.
• When operating in swimming pools, garden ponds and similar places, the device must be
provided with a residual current of not more than 30 mA by means of a residual-current-oper-
ated protective device.
• When operating outdoors, the electrical connections must be splash-proof; they must not lie
in water.
• Extension cords must have sufficient wire cross section; cable drums must be complete
unwound.

Operation

Filling and intake [suction]

Danger of damage to the device!
The pump should be filled with water after each new connection or in the event of
Attention!
water loss or air intake. Extended operation without a water refill (unsupervised dry
run) will destroy the pump!
1. Unscrew Pump cover. (6)
2. Fill completely with water.
3. Reinstall filter and screw Pump cover and seal back on.
4. If you want to shorten the intake time, fill the suction line as well.
5. Open pressure line (turn on water spigot or nozzle), so that air can escape during intake.
6. Switch the device on.
7. When water runs out evenly, turn the device off.